Author:
Tang Zi-Hui,Wang Lin,Zeng Fangfang,Li Zhongtao,Yu Xiaoling,Zhang Keqin,Zhou Linuo
Abstract
ObjectiveTo evaluate the reference values for short-term heart rate variability (HRV), estimate the performance of cardiovascular autonomic neuropathy (CAN) diagnostic tests in the absence of a gold standard, and assess CAN prevalence in our dataset.SettingCommunity and hospital health centre.ParticipantsOf 2092 subjects available for data analysis, 371 healthy subjects were selected so the reference values for the short-term HRV test could be evaluated. An external dataset contained 88 subjects who completed both the short-term HRV test and Ewing's test.InterventionCollection of information on clinical outcome.Primary and second outcome measuresCardiovascular autonomic function evaluated by using the short-term HRV test and/or Ewing's test.ResultsCut-off points of 356.13, 55.45 and 36.64 ms2 were set for total power, low frequency and high frequency (HF), respectively. The diagnostic test for CAN based on the mentioned reference value was created. The HRV test had a high sensitivity (80.01–85.09%) and specificity (82.30–85.20%) for CAN. In addition, the non-inferiority test rejected the null hypothesis that the performance of the HRV test was inferior to that of Ewing's test (p<0.05). The estimated CAN prevalence was 14.92% and 29.17% in the total sample and patients with diabetes, respectively.ConclusionsOur findings provided reference values for short-term HRV, which were used for the CAN diagnostic test with high sensitivity and specificity. The estimated CAN prevalence was high in the Chinese population.
Cited by
18 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献