An automated minimum retest interval rejection rule reduces repeat CRP workload and expenditure, and influences clinician-requesting behaviour

Author:

Waldron Jenna L,Ford Clare,Dobie Donald,Danks Graham,Humphrey Richard,Rolli Alain,Gama Rousseau

Abstract

AimsRepeat serum C-reactive protein (CRP) measurements on the same day or on consecutive days are of limited clinical value. Minimum retesting intervals are recommended for managing unnecessary repeat testing. As not previously reported, we studied the effect of minimum retesting interval test rejection on laboratory workload and expenditure and on clinician-requesting behaviour.MethodsIn a prospective study, we evaluated the effect of an automated 48 h CRP minimum retesting interval rule on inpatient and outpatient CRP workload and costs. Control data on inpatient and outpatient serum urea and electrolytes (UE) workload were collected during the study.ResultsOver 1 year, there was a 7.0% and 12.3% decrease in CRP requests and CRP tests analysed, respectively, following the introduction of the minimum retesting interval rule when compared to the 1 year baseline period. This equated to an estimated annual reduction in revenue costs of £10 500, but cash savings in consumable costs of £3000. There was no significant change in UE requests.ConclusionsWe report, for the first time, that automated minimum retesting interval rejection rules as a stand-alone strategy are a cheap and sustainable method for reducing unnecessary repeat CRP tests, resulting in small laboratory cash savings, more efficient use of laboratory resources and standardisation of patient care pathways. The minimum retesting interval rejection rule also altered clinician test-requesting behaviour towards more appropriate requesting.

Publisher

BMJ

Subject

General Medicine,Pathology and Forensic Medicine

Reference10 articles.

1. Department of Health. Report of the Review of NHS Pathology Services in England Chaired by Lord Carter of Coles . London: DOH, 2006. http://www.connectingforhealth.nhs.uk/systemsandservices/pathology/projects/nlmc/carterreview2006.pdf (last checked February 2014).

2. Population-based Study of Repeat Laboratory Testing

3. Changing clinicians’ laboratory test requesting behaviour: can the poacher turn gamekeeper?;Gama;Clin Lab,2001

4. Lang T . National minimum re-testing interval project: a final report detailing consensus recommendations for minimum re-testing intervals for use in clinical biochemistry. London: Association for Clinical Biochemistry and Laboratory Medicine, 2013. http://www.acb.org.uk/docs/default-source/guidelines/acb-mri-recommendations-a4-computer.pdf?sfvrsn=2 (last checked February 2014).

5. Laboratory demand management of repetitive testing—time for harmonisation and an evidenced based approach;Lang;Clin Chem Lab Med,2013