Real-world evaluation of Brainomix e-Stroke software

Author:

Mallon DermotORCID,Fallon Matthew,Blana Eirini,McNamara Cillian,Menon Arathi,Ip Chak Lam,Garnham Jack,Yousry Tarek,Cowley Peter,Simister RobertORCID,Doig DavidORCID

Abstract

Background and purposeBrainomix e-Stroke is an artificial intelligence-based decision support tool that aids the interpretation of CT imaging in the context of acute stroke. While e-Stroke has the potential to improve the speed and accuracy of diagnosis, real-world validation is essential. The aim of this study was to prospectively evaluate the performance of Brainomix e-Stroke in an unselected cohort of patients with suspected acute ischaemic stroke.MethodsThe study cohort included all patients admitted to the University College London Hospital Hyperacute Stroke Unit between October 2021 and April 2022. For e-ASPECTS and e-CTA, the ground truth was determined by a neuroradiologist with access to all clinical and imaging data. For e-CTP, the values of the core infarct and ischaemic penumbra were compared with those derived from syngo.via, an alternate software used at our institution.Results1163 studies were performed in 551 patients admitted during the study period. Of these, 1130 (97.2%) were successfully processed by e-Stroke in an average of 4 min. For identifying acute middle cerebral artery territory ischaemia, e-ASPECTS had an accuracy of 77.0% and was more specific (83.5%) than sensitive (58.6%). The accuracy for identifying hyperdense thrombus was lower (69.1%), which was mainly due to many false positives (positive predictive value of 22.9%). Identification of acute haemorrhage was highly accurate (97.8%) with a sensitivity of 100% and a specificity of 97.6%; false positives were typically caused by areas of calcification. The accuracy of e-CTA for large vessel occlusions was 91.5%. The core infarct and ischaemic penumbra volumes provided by e-CTP strongly correlated with those provided by syngo.via (ρ=0.804—0.979).ConclusionBrainomix e-Stroke software provides rapid and reliable analysis of CT imaging in the acute stroke setting although, in line with the manufacturer’s guidance, it should be used as an adjunct to expert interpretation rather than a standalone decision-making tool.

Publisher

BMJ

Subject

Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3