Incidence of faecal occult blood test interval cancers in population-based colorectal cancer screening: a systematic review and meta-analysis

Author:

Wieten ElsORCID,Schreuders Eline HORCID,Grobbee Esmée J,Nieboer Daan,Bramer Wichor M,Lansdorp-Vogelaar Iris,Bruno Marco J,Kuipers Ernst J,Spaander Manon C W

Abstract

ObjectiveFaecal immunochemical tests (FITs) are replacing guaiac faecal occult blood tests (gFOBTs) for colorectal cancer (CRC) screening. Incidence of interval colorectal cancer (iCRC) following a negative stool test result is not yet known. We aimed to compare incidence of iCRC following a negative FIT or gFOBT.DesignWe searched Ovid Medline, Embase, Cochrane Library, Science Citation Index, PubMed and Google Scholar from inception to 12 December 2017 for citations related to CRC screening based on stool tests. We included studies on FIT or gFOBT iCRC in average-risk screening populations. Main outcome was pooled incidence rate of iCRCs per 100 000 person-years (p-y). Pooled incidence rates were obtained by fitting random-effect Poisson regression models.ResultsWe identified 7 426 records and included 29 studies. Meta-analyses comprised data of 6 987 825 subjects with a negative test result, in whom 11 932 screen-detected CRCs and 5 548 gFOBT or FIT iCRCs were documented. Median faecal haemoglobin (Hb) positivity cut-off used was 20 (range 10–200) µg Hb/g faeces in the 17 studies that provided FIT results. Pooled incidence rates of iCRC following FIT and gFOBT were 20 (95% CI 14 to 29; I2=99%) and 34 (95% CI 20 to 57; I2=99%) per 100 000 p-y, respectively. Pooled incidence rate ratio of FIT versus gFOBT iCRC was 0.58 (95% CI 0.32 to 1.07; I2=99%) and 0.36 (95% CI 0.17 to 0.75; I2=10%) in sensitivity analysis. For every FIT iCRC, 2.6 screen-detected CRCs were found (ratio 1:2.6); for gFOBT, the ratio between iCRC and screen-detected CRC was 1:1.2. Age below 60 years and the third screening round were significantly associated with a lower iCRC rate.ConclusionA negative gFOBT result is associated with a higher iCRC incidence than a negative FIT. This supports the use of FIT over gFOBT as CRC screening tool.

Publisher

BMJ

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3