Normal values and regional differences in oesophageal impedance-pH metrics: a consensus analysis of impedance-pH studies from around the world

Author:

Sifrim DanielORCID,Roman Sabine,Savarino Edoardo,Bor Serhat,Bredenoord Albert J,Castell Donald,Cicala Michele,de Bortoli Nicola,Frazzoni MarzioORCID,Gonlachanvit SutepORCID,Iwakiri Katsuhiko,Kawamura Osamu,Krarup Anne,Lee Yeong YehORCID,Soon Ngiu Chai,Ndebia Eugene,Patcharatraku Tanisa,Pauwels Ans,Pérez de la Serna Julio,Ramos RosaORCID,Remes-Troche Jose Maria,Ribolsi Mentore,Sammon Alastair,Simren Magnus,Tack Jan,Tutuian Radu,Valdovinos Miguel,Xiao Yinglian,Zerbib FrankORCID,Gyawali C PrakashORCID

Abstract

ObjectiveLimitations of existing impedance-pH thresholds include small sample size of normative studies, inclusion of artefactual pH drops and incorrect identification of impedance reflux events. We aimed to obtain new impedance-pH thresholds from expert consensus analysis of tracings from a large number of healthy subjects.DesignOf 541 studies performed worldwide using two different systems (Diversatek, USA, and Laborie, Netherlands), 150 tracings with oesophageal diagnoses, behavioural disorders and study-related artefacts were excluded. The remainder studies were subject to two reviewer consensus analysis, in-person or through video conference, consisting of editing meals and pH drops, identification of impedance reflux and postreflux swallow-induced peristaltic wave (PSPW) using strict pre-established criteria and measurement of distal mean nocturnal baseline impedance (MNBI).ResultsConsensus analysis was performed in 391 tracings (age 32.7 years, range 18–71, 54.2% female). Normative thresholds were significantly different between Diversatek and Laborie (total acid exposure time: 2.8% and 5%; reflux episodes: 55 and 78; MNBI at 3 cm: 1400 and 1500 ohms, at 5 cm: 1400 and 1800 ohms). Males had higher acid exposure, more reflux episodes and lower MNBI. Significant regional differences were identified, including higher PSPW scores in Western countries, and higher MNBI in Asia using Diversatek, and higher acid exposure in the Netherlands, higher MNBI in Asia and South Africa, and lower MNBI in Turkey using Laborie.ConclusionNormal impedance-pH monitoring thresholds have regional and system-related differences. Clinical interpretation needs to use normal thresholds valid for the system used and world region, following careful editing of the tracings.

Funder

Queen Mary University of London

Publisher

BMJ

Subject

Gastroenterology

Cited by 63 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3