FRI0578 DEVELOPMENT OF A MOBILE APP AND WIRELESS SENSORS SYSTEM TO ASSESS SPINAL MOBILITY IN AXIAL SPONDYLOARTHRITIS: PRELIMINARY RESULTS.

Author:

Garrido-Castro J. L.,Torres Vidal F.,Ladehesa Pineda M.,Castro Villegas M. D. C.,Aranda-Valera I. C.,Ortega Castro R.,Gonzalez-Navas C.,Collantes Estevez E.

Abstract

Background:Spinal mobility is an important assessment outcome in axial spondyloarthritis (axSpA). Until now, conventional metrology (Schober test, lateral flexion, BASMI, …) has been used to assess spinal mobility, however, new technologies have been developed that provide better accuracy, reliability and responsiveness. Motion capture has been validated and Inertial Measurement Unit (IMU) sensors, appears to be a promising alternative. To use this IMU sensors in axSpA patients, wireless systems must be developed and validated allowing to doctors and patients to use them in hospitals and at home.Objectives:To develop an easy to use mobile app and IMU sensors system for analyse mobility for axSpA patients.Methods:A mobile app has been developed (iUCOTrack) that communicates with two IMU sensors (Shimmer 3©, Fig-a). These sensors are attached in different locations: at forehead and T12 for cervical mobility (Fig-c) and T12 and Sacrum for thoracolumbar mobility (Fig-b). The app provides mobility results for the different tests (Fig-d) and store results in the cloud. Validation tests of these sensors, using Matlab©, were done previously [1]. Our study test the validity of this app against a motion capture system, the UCOTrack®, and its metrology index, the UCOASMI [2], and conventional metrology as reference standards. Patiens with axSpA were recruited consecutively from the COSPAR cohort. Conventional metrology, PRO questionnaires and mobility (Cervical and thoracolumbar - flexion, lateral bending, rotation) using the iUCOTrack app and the UCOTrack were registered. Intraclasss Correlation Coefficients (ICC 3,1) between systems and correlations (spearman) with other axSpA outcome measures were performed for testing validity.Results:15 axSpA patients (47% female, age 52±12 years, disease duration 21±16 years) were included. Table shows ROM (SD) in degrees obtained for cervical and thoracolumbar spine measured by motion capture (UCOTrack) and the app (iUCOTrack). In the last column appears the UCOASMI (SD) calculated using angles obtained by each system. All ICC were good (ICC>0.8), and correlations were significant (p<0.05, r>0.8) specially the UCOASMI. Cervical rotation using a goniometer was 106.2±36°, with a significant correlation with both systems (p<0.05; r>0.8). Schober correlation with lumbar flexion was poor (NS;r>0.5) but a good correlation appeared with lateral flexion (p<0.01;r>0.9). Mean BASMI was 4.0± 1.8 with an excellent correlation with UCOASMI measured by Mocap (p<0.01;r=0.93) and by IMU (p<0.001;r=0.98).CervicalThoracolumbarFlexRotLatFlexRotLatUCOASMIUCOTrack79.5(24.7)109.8(29.6)62.5(25.1)100.7(21.6)61.8(25.3)54.7(22.9)6.07(1.66)iUCOTrack83.0(33.6)112.6(44.3)73.9(29.7)114.4(28.1)51.4(16.1)59.4(15.4)6.15(1.65)ICC0.8640.9030.8120.9360.7980.9010.970Corr0.89*0.96**0.82*0.97**0.88*0.97***0.97**Conclusion:New metrology tools are needed to improve features of convencional metrology. Motion Capture has proved to be valid but has feasibility problems. IMU sensor based systems provide similar results to motion capture but it can be faster and cheaper. A system based on mobile app connected to wireless IMU sensors could be a solution to improve metrology in axSpA. Further studies and developments are needed to introduce these technologies in research and clinical daily practice.References:[1] Use of inertial sensors for the assessment of spinal mobility in axial spondyloarthritis patients. Rehabilitacion. 2018 Apr;52(2):100-106.[2] High Reproducibility of an Automated Measurement of Mobility for Patients with Axial Spondyloarthritis. J Rheumatol. 2018 Oct;45(10):1383-1388.Acknowledgments:Funded by Junta de Andalucia (PIN-0079-2016) and ISCIII (DTS18/00046).Disclosure of Interests:Juan L. Garrido-Castro: None declared, Francisco Torres Vidal: None declared, MLourdes Ladehesa Pineda: None declared, María del Carmen Castro Villegas: None declared, Inmaculada Concepcion Aranda-Valera: None declared, Rafaela Ortega Castro: None declared, Cristina Gonzalez-Navas: None declared, Eduardo Collantes Estevez Grant/research support from: ROCHE and Pfizer, Speakers bureau: ROCHE, Lilly, Bristol and Celgene

Publisher

BMJ

Subject

General Biochemistry, Genetics and Molecular Biology,Immunology,Immunology and Allergy,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3