Prevalence of iatrogenic atrial septal defects (iASD) after mitral valve (MV) transcatheter edge-to-edge repair (TEER) in the long-term follow-up

Author:

Paukovitsch MichaelORCID,Schneider Leonhard Moritz,Reichart Christine,Nita Nicoleta,Rottbauer Wolfgang,Keßler Mirjam,Markovic SinisaORCID

Abstract

ObjectivesTo investigate prevalence of iatrogenic atrial septal defects (iASDs) after mitral valve (MV) transcatheter edge-to-edge repair (TEER) with the MitraClip in the long-term follow-up.BackgroundMV TEER requires transseptal puncture using a large 22 F sheath. Prevalence, impact and haemodynamic effects of these iASDs remain unknown in the long-term follow-up.MethodsThis prospective study enrolled patients who had undergone first-time TEER at our university hospital between January 2017 and June 2018 for a clinical long-term follow-up study. Prevalence of iASD was investigated 12 months post-TEER using transoesophageal echocardiography (TEE). Study protocol further consisted of transthoracic echocardiography (TTE) and exercise testing. Incidence of all-cause death was compared 12 months post-TEE follow-up. This study was approved by local ethics committee.Results48 patients participated in clinical follow-up examinations. Median time between TEER and clinical follow-up examination (TEE, TTE, exercise testing) was 19.5 (IQR: 7.0) months after TEER. Persistent iASD was found in 41.7% of patients. TEER was found to be equally effective in reducing MR and clinical symptoms in both groups at baseline as well as follow-up. Procedural fluoroscopy and device times were significantly longer in the iASD group. MR reduction and functional status (New York Heart Association Class, 6 Minute Walking Test distance) were similar in both groups. Nevertheless, a significant decrease in systolic pulmonary artery pressure (sPAP) and significantly smaller atrial diameters were observed in patients with iASD at follow-up.ConclusionPrevalence of iASDs after TEER in long-term follow-up was about 41%. Although a significant reduction of sPAP and better left atrial reverse remodelling were accomplished in patients with iASD, clinical impact appears low. Manipulation at the atrial septum might play a key role in creating persisting iASD.

Publisher

BMJ

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3