Association between implanted cardioverter-defibrillators and mortality for patients with left ventricular ejection fraction between 30% and 35%

Author:

Wasfy Jason HORCID,Achanta Aditya,Hidrue Michael K,Urbut Sarah,Axtell Andrea L,Berman Adam N,Zhao Yunong,Chen Julian,Gustus Sarah,Picard Michael H

Abstract

BackgroundConsensus guidelines support the use of implanted cardioverter-defibrillators (ICD) for primary prevention of sudden cardiac death in patients with either non-ischaemic or ischaemic cardiomyopathy with left ventricular ejection fraction (LVEF) ≤35%. However, evidence from trials for efficacy specifically for patients with LVEF near 35% is weak. Past trials are underpowered for this population and future trials are unlikely to be performed.MethodsPatients with lowest LVEF between 30% and 35% without an ICD prior to the lowest-LVEF echo (defined as ‘time zero’) were identified by querying echocardiography data from 28 November 2001 to 9 July 2020 at the Massachusetts General Hospital linked to ICD treatment status. To assess the association between ICD and mortality, propensity score matching followed by Cox proportional hazards models considering treatment status as a time-dependent covariate was used. A secondary analysis was performed for LVEF 36%–40%.ResultsInitially, 526 440 echocardiograms representing 266 601 unique patients were identified. After inclusion and exclusion criteria were applied, 6109 patients remained for the analytical cohort. In bivariate unadjusted comparisons, patients who received ICDs were substantially more often male (79.8% vs 65.4%, p<0.0001), more often white (87.5% vs 83.7%, p<0.046) and more often had a history of ventricular tachycardia (74.5% vs 19.1%, p<0.0001) and myocardial infarction (56.1% vs 38.2%, p<0.0001). In the propensity matched sample, after accounting for time-dependence, there was no association between ICD and mortality (HR 0.93, 95% CI 0.75 to 1.15, p=0.482).ConclusionsICD therapy was not associated with reduced mortality near the conventional LVEF threshold of 35%. Although this treatment design cannot definitively demonstrate lack of efficacy, our results are concordant with available prior trial data. A definitive, well-powered trial is needed to answer the important clinical question of primary prevention ICD efficacy between LVEF 30% and 35%.

Funder

American Heart Association

CDA

Publisher

BMJ

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3