Functional assessment of myocardial ischaemia by intracoronary ECG

Author:

Bigler Marius RetoORCID,Stoller Michael,Praz Fabien,Siontis George C M,Grossenbacher Raphael,Tschannen Christine,Seiler Christian

Abstract

IntroductionIn patients with chronic coronary syndrome, percutaneous coronary intervention targets haemodynamically significant stenoses, that is, those thought to cause ischaemia. Intracoronary ECG (icECG) detects ischaemia directly where it occurs. Thus, the goal of this study was to test the accuracy of icECG during pharmacological inotropic stress to determine functional coronary lesion severity in comparison to the structural parameter of quantitative angiographic per cent diameter stenosis (%S), as well as to the haemodynamic indices of fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR).MethodThe primary study endpoint of this prospective trial was the maximal change in icECG ST-segment shift during pharmacological inotropic stress induced by dobutamine plus atropine obtained within 1 min after reaching maximal heart rate(=220 - age). IcECG was acquired by attaching an alligator clamp to the angioplasty guidewire positioned downstream of the stenosis. For the pressure-derived stenosis severity ratios, coronary perfusion pressure and simultaneous aortic pressure were continuously recorded.ResultsThere was a direct linear relation between icECG ST-segment shift and %S: icECG=−0.8+0.03*%S (r2=0.164; p<0.0001). There were inverse linear correlations between FFR and %S: FFR=1.1–6.1*10–3*%S (r2=0.494; p<0.0001), and between iFR and %S: iFR=1.27–8.6*10–3*%S (r2=0.461; p<0.0001). Using a %S-threshold of ≥50% as the reference for structural stenosis relevance, receiver operating characteristics-analysis of absolute icECG ST-segment shift during hyperemia showed an area under the curve (AUC) of 0.678±0.054 (p=0.002; sensitivity=85%, specificity=50% at 0.34 mV). AUC for FFR was 0.854±0.037 (p<0.0001; sensitivity=64%, specificity=96% at 0.78), and for iFR it was 0.816±0.043 (p<0.0001;sensitivity=62%, specificity=96% at 0.83).ConclusionsHyperaemic icECG ST-segment shift detects structurally relevant coronary stenotic lesions with high sensitivity, while they are identified highly specific by FFR and iFR.

Funder

Schweizerische Herzstiftung

Publisher

BMJ

Subject

Cardiology and Cardiovascular Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3