Comparative Evaluation of Biomechanical Characteristics of Acellular Dermal Matrix for Hernioplasty

Author:

Melkonian K. I.1ORCID,Popandopulo K. I.1ORCID,Bazlov S. B.1ORCID,Rusinova T. V.1ORCID,Moskalyuk O. A.2ORCID,Bykov I. M.1ORCID

Affiliation:

1. Kuban State Medical University

2. St. Petersburg State University of Industrial Technologies and Design

Abstract

Background. With the introduction of synthetic mesh implants into clinical practice, the recurrence rate of postoperative ventral hernias was signifi cantly reduced. The extensive use of synthetic implants led to the development of specifi c complications. The development of biological implants, based on extensively purifi ed decellularized collagen matrix of xenogeneic origin is highly relevant due to the fact that, unlike synthetic analogues, they have a biological origin and biodegrade in a natural way, gradually being replaced with newly formed connective tissue. The use of bioprostheses reduces the risk of complications.Objectives. To conduct a comparative evaluation of the biomechanical characteristics of acellular dermal matrix, obtained by detergent-enzymatic decellularization, and commercially distributed Permacol™ matrix.Methods. Acellular dermal matrix (ADM) was created by using samples of native skin of pig of Landras breed aged 4 months. The dermis was processed by means of detergent-enzymatic method. In order to evaluate and compare the mechanical properties of acellular dermal matrix, the biological samples were divided into 2 groups of 15 samples each. The fi rst group included acellular dermal matrix samples, the second group — native samples of pigs unprocessed dermis. The control group consisted of samples of PermacolTM Surgical Implant, xenotransplant for hernioplasty approved for use in the Russian Federation (Covidien, France). All samples were tested wet using universal testing instrument Instron 1122. MedCalc Statistical Software (Belgium) was used for statistical processing of the study results.Results. In the present study, pig dermis was processed using a detergent-enzymatic method to produce ADM. Routine histological examination confi rmed the removal of all cellular elements, and at the same time it was proven that the native structure of the dermis remained intact during its processing. The mechanical characteristics of xenogenic ADM were further determined. Its tensile strength was 9.1 ± 0.6 MPa (910 N/cm2 ), elongation to break was 21.1 ± 2.3%, and elastic modulus was 50.0 ± 1.6 MPa. These characteristics largely corresponded to the strength characteristics of native pig dermis and far exceeded the necessary physiological parameters. PermacolTM control was tested in two directions (longitudinal and transverse). In the longitudinal direction, the sample had higher mechanical characteristics: strength — 12.0 ± 1.7 MPa, elongation to break — 29.7 ± 2.4%, stiffness modulus — 47.2 ± 6.5 MPa. In the transverse direction, all indicators were 1.5–2 times lower.Conclusion. The developed xenogeneic biological implant in the form of ADM demonstrates rather good characteristics of plasticity, tensile strength and elasticity, to be used as a biological endoprosthesis for plasty of hernia defects of the abdominal wall of any size and shape.

Publisher

Kuban State Medical University

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3