Improvement of Performance for Musculoskeletal Robots by Mountable Actuator Units
-
Published:2010-06-20
Issue:3
Volume:22
Page:391-401
-
ISSN:1883-8049
-
Container-title:Journal of Robotics and Mechatronics
-
language:en
-
Short-container-title:J. Robot. Mechatron.
Author:
Ohta Shigeki, ,Hongo Kazuo,Nakanishi Yuto,Mizuuchi Ikuo,Inaba Masayuki,
Abstract
It is very difficult to decide and to optimize the layouts of muscle which may completely fulfill the demands for muscle tension and joint stiffness of tendon driven systems at the design stage. However, muscle that can be easily added to the system depending on the situation makes it possible to seek optimal layouts of muscle through experimentation. This paper describes the development of two types of actuator units which can be easily added to the tendon-driven system. One is the regulable stiffness actuator unit which a nonlinear spring element is built into, and the other is an actuator unit which is smaller than actuator unit with regulable stiffness. To verify the effects of the actuator units on performance, we experiment with a musculoskeletal humanoid, Kojiro, to which the two types of actuator units developed are added.
Publisher
Fuji Technology Press Ltd.
Subject
Electrical and Electronic Engineering,General Computer Science
Reference12 articles.
1. T. Sato, H. Uchino, H. Tatsukawa, K. Asaki, H. Noguchi, Y. Matsunobu, H. Morishita, and T. Mori, “Behavior Understanding Functions for Adaptive Personal Support System (Robotic Room 3),” IEICE. PRMU, Vol.100, No.443, pp. 21-27, 2000. (in Japanese) 2. K. Hongo, M. Yoshida, Y. Nakanishi, I. Mizuuchi, and M. Inaba, “Development of Bilateral Wearable Device “Kento” for Control Robots using Muscle Actuator Modules,” In 18th IEEE Int. Symposium on Robot and Human Interactive Communication, pp. 897-902, September 2009. 3. I. Mizuuchi, Y. Nakanishi, Y. Sodeyama, Y. Namiki, T. Nishino, N. Muramatsu, J. Urata, K. Hongo, T. Yoshikai, and M. Inaba, “An Advanced Musculoskeletal Humanoid Kojiro,” In Proc. of the 2007 IEEE-RAS Int. Conf. on Humanoid Robot, pp. 294-299, 2007. 4. M. Onishi, Z. W. Luo, T. Odashima, S. Hirano, K. Tahara, and T. Mukai, “Generation of Human Care Behaviors by Human-Interactive Robot RI-MAN,” In Proc. of the 2007 IEEE Int. Conf. on Robotics & Automation, pp. 3128-3129, 2007. 5. N. Hogan, “Impedance Control: An Approach to Manipulation: Parts I, II, III,” J. of Dynamic Systems, Measurement, and Control, Vol.107, pp. 1-24, 1985.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|