Development of Intraoperative Plantar Pressure Measurement System Considering Weight Bearing Axis and Center of Pressure
-
Published:2022-12-20
Issue:6
Volume:34
Page:1318-1328
-
ISSN:1883-8049
-
Container-title:Journal of Robotics and Mechatronics
-
language:en
-
Short-container-title:J. Robot. Mechatron.
Author:
Hosoi Izumu,Matsumoto Takumi,Chang Song Ho,An Qi,Sakuma Ichiro,Kobayashi Etsuko, , , ,
Abstract
To prevent postoperative complications in corrective surgery for foot deformities such as hallux valgus and pes planus, it is critical to quantitatively predict the postoperative standing-position plantar pressure distribution during the operation. The authors have previously proposed an intraoperative plantar pressure measurement system (IPPM) that allows for the measurement of a supine patient’s plantar pressure distribution that is equivalent to that in the standing position. This system consists of an IPPM device comprising of a force plate and pressure distribution sensor, an optical three-dimensional position measurement device, a navigation monitor, and a PC. The plantar pressure distribution in the standing position is reproduced by navigating the operator, as he or she presses the IPPM device against the patient’s sole so that the weight-bearing axis (floor reaction force vector) and femoral head center are as close to each other as possible. However, in our previous study, the reproducibility of the standing position plantar pressure distribution was insufficient. Therefore, in the present study, we add a navigational function that can be used to bring the centers of pressure in the standing position and under measurement, as well as to correct the IPPM’s self-weight in the measured force. The improved device was used in an experiment with nine healthy subjects, and the similarity of the plantar pressure distribution in the standing and supine positions was evaluated using normalized cross-correlation, yielding an average of 0.90. Furthermore, in an evaluation experiment with ten orthopedic surgeons, it was observed that using the system reproduced the plantar pressure distribution significantly better than when the system was not used. These results indicate that the present system can predict the plantar pressure distribution in the standing position. We believe that this system can contribute to reducing complications after foot surgery.
Funder
Japan Agency for Medical Research and Development
Publisher
Fuji Technology Press Ltd.
Subject
Electrical and Electronic Engineering,General Computer Science
Reference22 articles.
1. G. Bonney and I. Macnab, “Hallux Valgus and Hallux Rigidus,” The J. of Bone and Joint Surgery, Vol.34-B, No.3, pp. 366-385, doi: 10.1302/0301-620X.34B3.366, 1952. 2. E. Roddy, W. Zhang, and M. Doherty, “Prevalence and associations of hallux valgus in a primary care population,” Arthritis Care and Research, Vol.59, No.6, pp. 857-862, doi: 10.1002/art.23709, 2008. 3. T. Matsumoto, J. Higuchi, Y. Maenohara, S. H. Chang, T. Iidaka, C. Horii et al., “The discrepancy between radiographically-assessed and self-recognized hallux valgus in a large population-based cohort,” BMC Musculoskelet. Disord., Vol.23, No.1, Article No.31, doi: 10.1186/s12891-021-04978-z, 2022. 4. K. J. Mickle, B. J. Munro, S. R. Lord, H. B. Menz, and J. R, Steele, “Gait, balance and plantar pressures in older people with toe deformities,” Gait and Posture, Vol.34, No.3, pp. 347-351, doi: 10.1016/j.gaitpost.2011.05.023, 2011. 5. H. B. Menz and S. R. Lord, “Foot pain impairs balance and functional ability in community-dwelling older people,” J. Am. Podiatr. Med. Assoc., Vol.91, No.5, pp. 222-229, doi: 10.7547/87507315-91-5-222, 2001.
|
|