Application and Mechanical Evaluation of Polyarylate Fiber Rope in Wire Drive Mechanism of Robotic Surgical Instruments

Author:

Nojima Kanta1,Tadano Kotaro2ORCID,Haraguchi Daisuke1ORCID

Affiliation:

1. National Institute of Technology, Tokyo College, 1220-2 Kunugida-machi, Hachioji, Tokyo 193-0997, Japan

2. Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503, Japan

Abstract

In this study, a polyarylate fiber rope, which is a high-strength synthetic fiber rope, is used in the wire drive mechanism of a multi-degree of freedom (DOF) robotic forceps to evaluate its mechanical practicability. Using a nonconducting material for the drive wire, different from typical use of metallic wires made of stainless steel and tungsten, a technology is developed to simplify the insulation structure significantly, decrease the diameter of the robotic surgical instrument, and lower its cost. In this study, first, a prototype of the multi-DOF robotic forceps equipped with a polyetheretherketone (PEEK) resin flexible wrist joint part with an external diameter of 5 mm is manufactured. The prototype is used to evaluate the assembling of a polyarylate fiber rope with a diameter of 0.34 mm in a multi-DOF mechanism and examine the endurance of the rope to mechanical motions under a single-use assumption. As fastening structures to assemble the rope – a crimp terminal using a hollow pipe and a thread knot – are examined individually by assembling them in the prototype robotic forceps and conducting strength tests of the tension generated by the drive. The test results show that the thread knot method exerts a stabler fastening strength than the hollow pipe method. However, a problem of the former is that the wire may break because of its strong contact with the edge of the hole of the wire guide. Subsequently, to evaluate the endurance of the rope to single-use operation motion, operation tests are conducted by implementing reciprocating bending motions of the flexible wrist joint part of the robotic forceps 1,000 times. The assembled rope endures the sliding within the flexible wrist joint part and the contact loading with the guide part and the fixed structure within the cartridge repeatedly. The endurance operation test results confirm that the drive transmission of the polyarylate fiber rope has sufficient mechanical endurance to 1,000 reciprocating bending motions of the PEEK flexible wrist joint part.

Funder

Research Center for Biomedical Engineering in Japan

Publisher

Fuji Technology Press Ltd.

Subject

Electrical and Electronic Engineering,General Computer Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3