Application and Mechanical Evaluation of Polyarylate Fiber Rope in Wire Drive Mechanism of Robotic Surgical Instruments
-
Published:2023-04-20
Issue:2
Volume:35
Page:461-469
-
ISSN:1883-8049
-
Container-title:Journal of Robotics and Mechatronics
-
language:en
-
Short-container-title:J. Robot. Mechatron.
Author:
Nojima Kanta1, Tadano Kotaro2ORCID, Haraguchi Daisuke1ORCID
Affiliation:
1. National Institute of Technology, Tokyo College, 1220-2 Kunugida-machi, Hachioji, Tokyo 193-0997, Japan 2. Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503, Japan
Abstract
In this study, a polyarylate fiber rope, which is a high-strength synthetic fiber rope, is used in the wire drive mechanism of a multi-degree of freedom (DOF) robotic forceps to evaluate its mechanical practicability. Using a nonconducting material for the drive wire, different from typical use of metallic wires made of stainless steel and tungsten, a technology is developed to simplify the insulation structure significantly, decrease the diameter of the robotic surgical instrument, and lower its cost. In this study, first, a prototype of the multi-DOF robotic forceps equipped with a polyetheretherketone (PEEK) resin flexible wrist joint part with an external diameter of 5 mm is manufactured. The prototype is used to evaluate the assembling of a polyarylate fiber rope with a diameter of 0.34 mm in a multi-DOF mechanism and examine the endurance of the rope to mechanical motions under a single-use assumption. As fastening structures to assemble the rope – a crimp terminal using a hollow pipe and a thread knot – are examined individually by assembling them in the prototype robotic forceps and conducting strength tests of the tension generated by the drive. The test results show that the thread knot method exerts a stabler fastening strength than the hollow pipe method. However, a problem of the former is that the wire may break because of its strong contact with the edge of the hole of the wire guide. Subsequently, to evaluate the endurance of the rope to single-use operation motion, operation tests are conducted by implementing reciprocating bending motions of the flexible wrist joint part of the robotic forceps 1,000 times. The assembled rope endures the sliding within the flexible wrist joint part and the contact loading with the guide part and the fixed structure within the cartridge repeatedly. The endurance operation test results confirm that the drive transmission of the polyarylate fiber rope has sufficient mechanical endurance to 1,000 reciprocating bending motions of the PEEK flexible wrist joint part.
Funder
Research Center for Biomedical Engineering in Japan
Publisher
Fuji Technology Press Ltd.
Subject
Electrical and Electronic Engineering,General Computer Science
Reference22 articles.
1. K. Aizawa, D. Haraguchi, and K. Tadano, “Load Reduction Control on Tool-Insertion Port for Laparoscopic Surgical Robot Using Semi-Active Joints,” J. Robot. Mechatron., Vol.32, No.5, pp. 1000-1009, 2020. https://doi.org/10.20965/jrm.2020.p1000 2. M. Suzuki, T. Takahashi, and S. Aoyagi, “Fabrication and Characterization of a Biodegradable Hollow Microneedle from Chitosan,” J. Robot. Mechatron., Vol.32, No.2, pp. 401-407, 2020. https://doi.org/10.20965/jrm.2020.p0401 3. S. V. Bandara and J. Arata, “3.5mm Soft Robotic Forceps for Minimally Invasive Surgery,” Systems, Control and Information, Vol.63, No.10, pp. 420-423, 2019. https://doi.org/10.11509/isciesci.63.10_420 4. C. Ishii, K. Kobayashi, Y. Kamei, and Y. Nishitani, “Robotic Forceps Manipulator With a Novel Bending Mechanism,” IEEE/ASME Trans. on Mechatronics, Vol.15, No.5, pp. 671-684, 2010. https://doi.org/10.1109/TMECH.2009.2031641 5. C. Forbrigger et al., “Cable-less, Magnetically-Driven Forceps For Minimally Invasive Surgery,” IEEE Robotics and Automation Letters, Vol.4, No.2, pp. 1202-1207, 2019. https://doi.org/10.1109/LRA.2019.2894504
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|