Determination of the optimal concentration of ozone–containing mixture for safe use in clinical conditions

Author:

Kostylev M. V.ORCID,Terekhov G. V.ORCID,Savytska I. M.ORCID,Simulyk E. V.ORCID,Furmanov O. Yu.ORCID,Grigorieva N. Yu.ORCID

Abstract

Objective. To study the effect of ozone during hyperbaric oxygenation with an ozone–containing mixture on the respiratory system and stress response organs of experimental animals, to select the optimal parameters of ozone generation and supply by the POS–1 apparatus to perform this procedure in a confined space without harming the health of the patient and medical staff. Materials and methods. Experimental studies were performed on 20 white laboratory rats divided into two groups. In group 1, 10 animals breathed the ozone–containing mixture for 7 days, each session lasted 15 minutes. In the 2nd group, 10 animals breathed the ozone–containing vapour–water mixture for 7 days, each session also lasted 15 minutes. All animals were kept in a semi–hermetic box with a volume of 0.042 m3 with an ozone supply of 500 mg/h, which exceeds the maximum permissible concentration (0.16 mg/m3 ) by a factor of 2. The pressure of the gas mixture in the box with the animals was equal to atmospheric pressure.The animals were withdrawn from the experiment on the 3rd, 7th and 14th day by injecting an excessive dose of 5.0% sodium thiopental solution. The trachea, lungs, liver, kidneys, spleen, heart, stomach, pancreas, and adrenal glands were autopsied and taken for histological examination. The ozone concentration in the room during the experiment was measured using a SAMI 100S ozone concentration meter. Results. Exposure to the ozone–containing mixture did not cause pathological changes in the organs and systems of the experimental animals, as well as a significant stress response, which proves the safety of the technique in confined spaces. The method of treatment of infectious and purulent complications proposed in previous studies does not harm the health of the patient and medical staff and can be recommended for use in clinical practice without additional measures for the utilisation of ozone produced by the POS–1 apparatus. Conclusions. The optimal parameters of ozone production and supply in the ozone–containing mixture for hyperbaric oxygenation in a confined space without harming the health of the patient and medical staff have been proposed. The ozone–containing steam–water mixture can be recommended for use in clinical practice in conditions of massive tissue infection as a factor of external physical influence with pronounced bactericidal and bacteriostatic properties. The concentration of residual ozone in the room after the therapeutic procedure does not exceed the permissible level and does not harm the health of the patient and medical staff.

Publisher

Liga-Inform, Ltd.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3