Efficacy of bedside optic nerve sheath diameter measurement in differentiating provoked seizure from unprovoked seizure in the emergency department

Author:

Yılmaz Fevzi1ORCID,Sonmez Bedriye Muge2,Kavalci Cemil1,Arslan Engin Deniz1,Caliskan Gulsum1,Beydilli Inan1

Affiliation:

1. From the Department of Emergency Medicine, Antalya Training and Research Hospital, Antalya, Turkiye

2. From the Department of Emergency Medicine, Ankara Dışkapı Yıldırım Beyazıt Eğitim ve Araştırma Hastanesi, Ankara, Turkiye

Abstract

BACKGROUND: Emergency departments (EDs) are typically the first medical contact for seizure patients, and early diagnosis and treatment is primarily the responsibility of emergency physicians. OBJECTIVES: Demonstrate the efficacy of bedside ocular ultrasonography for optic nerve sheath diameter (ONSD) measurement in differentiating provoked seizure from unprovoked seizure in the ED. DESIGN: Prospective observational study SETTINGS: Tertiary care hospital PATIENTS AND METHODS: Patients presenting to the ED with seizure were divided into two groups according to medical history, physical examination, laboratory results, cranial computed tomography findings and electroencephalography results. Patients with seizures that did not have a specific cause (unprovoked) were compared with patients who had seizures caused by underlying pathology (provoked). The measurement of the ONSD was taken at the bedside within 30 minutes of arrival. The study compared the ONSD values, age, sex, type of seizure, and Glasgow Coma Score between the two groups. MAIN OUTCOME MEASURE: Efficacy of ONSD to distinguish between provoked and unprovoked seizures. SAMPLE SIZE: 210 patients RESULTS: One hundred and fourteen (54.3%) patients were in the provoked seizure group and 96 (45.7%) were in the unprovoked seizure group. The ONSD measurements were significantly higher in the provoked seizure group compared with the unprovoked seizure group (median 6.1 mm vs. 5.2 mm, P <.001). The cut-off value of ONSD higher than 5.61 was significantly associated with the prediction of the provoked seizure ( P <.001). The area under the curve value was 0.882 (95% CI: 0.830-0.922) with a sensitivity of 86.5 and specificity of 78.9%. CONCLUSIONS: Bedside ONSD measurement by means of ocular ultrasound is an effective method for differentiating provoked seizure from unprovoked seizure. LIMITATIONS: Statistical significance of age on ONSD and exclusion of pediatric patients. CONFLICT OF INTEREST: None.

Publisher

King Faisal Specialist Hospital and Research Centre

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3