Abstract

BACKGROUND: Ultraportable or pocket handheld ultrasound devices (HUD) may be useful for large-scale abdominal aortic aneurysm screening. However, the reproducibility of measurements has not been compared with conventional cart-based ultrasound machines. OBJECTIVES: Investigate the intra- and inter-operator reproducibility of a HUD compared with a conventional ultrasound machine for aortic screening. DESIGN: Analytical, cross-sectional. SETTING: Ultrasound department at a large tertiary care hospital in Riyadh. PATIENTS AND METHODS: Eligible male participants aged ≥60 years were invited to participate upon arriving for a non-vascular ultrasound appointment. Three repeated anteroposterior measurements of the transverse aorta were made at the proximal and distal locations for each machine before repeating the measurements on a subset of participants by a second blinded operator. Intraclass correlation coefficients (ICC) and the Bland-Altman method were used to analyze reproducibility. MAIN OUTCOME MEASURE: Inter-system and intra- and inter-operator ICCs. SAMPLE SIZE: 114 males with repeated measurements by second operator on a subset of 35 participants. RESULTS: The median age (interquartile range) of participants was 68 years (62–74 years). The intra- and inter-operator ICCs were all >0.800 showing almost perfect agreement except for the inter-operator reproducibility at the proximal location using a conventional machine (ICC= 0.583, P =.007) and the Butterfly device (ICC=0.467, P =.037). The inter-system ICCs (95% CI) were 0.818 (0.736–0.874) and 0.879 (0.799–0.924) at the proximal and distal locations, respectively. The mean difference in aortic measurement between the ultrasound systems was 0.3 mm (1.7%) in the proximal location and 0.6 mm (3.6%) in the distal location. In total, >91% of the difference in measurements between the machines was <3 mm. The mean scanning time was 4:16 minutes for the conventional system and 3:53 minutes for the HUD ( P =.34). CONCLUSIONS: Abdominal aortic screening using a HUD was feasible and reliable compared with a conventional ultrasound machine. A pocket HUD should be considered for large-scale screening. LIMITATIONS: No cases of abdominal aortic aneurysm in the sample and lack of blinding. CONFLICT OF INTEREST: None.

Publisher

King Faisal Specialist Hospital and Research Centre

Subject

General Medicine

Reference33 articles.

1. Primary care screening for abdominal aortic aneurysm: updated evidence report and systematic review for the US Preventive Services Task Force;Guirguis-Blake JM;Jama.,2019

2. Screening for abdominal aortic aneurysms: single centre randomised controlled trial;Lindholt JS;BMJ.,2005

3. Screening results from a large United Kingdom abdominal aortic aneurysm screening center in the context of optimizing United Kingdom National Abdominal Aortic Aneurysm Screening Programme protocols;Benson RA;Journal of Vascular Surgery.,2016

4. Screening for abdominal aortic aneurysm in the Jeddah area, western Saudi Arabia;Zahrani HA;Cardiovascular Surgery.,1996

5. Incidence of Finding Abdominal Aortic Aneurysm in Abdominal Computed Tomography Scan and its Implication on its Prevalence in Saudi Arabia;Alomran F;The Arab Journal of Interventional Radiology.,2018

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献