Color matching of full ceramic versus metal-ceramic crowns - a spectrophotometric study

Author:

Greța Delia Cristina,Gasparik CristinaORCID,Colosi Horațiu Alexandru,Dudea Diana

Abstract

Background and aims. To verify the color match of metal-ceramic and full ceramic crowns, using instrumental methods. Methods. A number of 153 teeth (anterior and posterior teeth), in 62 patients,  were restored with metal ceramic (MC, n=119), pressed-ceramic (PC, n=28), and zirconia-ceramic (ZC, n=6) full coverage crowns. The shade of a reference natural tooth was recorded instrumentally with a dental spectrophotometer (Vitaeasyshade Advance 4.0) in “single tooth measurement”, which provided  the base color in Vita Classic (VC) and Vita 3D Master shades (3D).  For verifying the outcome of the restoration “verify restoration” mode was used, and ΔE values were recorded for both VC and 3D Master shade guides. Moreover, matching symbols were also recorded (***=good, **=fair, *=poor). Descriptive statistics was performed and data were analyzed (One-sample z-Test, α=0.05) for comparison with visual thresholds in dentistry (Perceptibility Threshold – PT=1.2 and Acceptability Threshold – AT=2.7). Results. The data did not follow a normal distribution (Kolmogorov-Smirnov test, p<0.05). Recorded color difference was significantly higher than PT and AT, for all types of restorations, regardless of the  coding system (p<0.05). For MC crowns in 2.52% (4.20% for 3D) of the cases the color difference was smaller than PT, in 19.32% (the same for 3D) of cases was between PT and AT, and in 78.15% (76.47% for 3D) of cases was higher than the AT. For PC crowns in 3.57% (0% for 3D) of the cases the color difference was smaller than PT, in 25% (32.14% for 3D) of cases was between PT and AT, and in 71.42% (67.85% for 3D) of cases was higher than the AT. In the case of ZC crowns none of the restorations had color difference smaller than PT, but in 16.66% of cases was between PT and AT, and in 83.33% of cases was higher than the AT, for both VC and 3D. Conclusion. Within the limitations of the study, a better color match was achieved in the case of pressed ceramic crowns, made of lithium disilicate.  In most of the situations the color difference between the restoration and the reference tooth exceeded the perceptibility thresholds, but the matching was recorded as “fair” by the spectrophotometer.     

Publisher

Clujul Medical

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3