Influence of the irradiation geometry on the severity of acute radiation damage

Author:

Golikov V. Yu.1,Vodovatov A. V.2

Affiliation:

1. Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing

2. Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing; Saint-Petersburg State Pediatric Medical University

Abstract

The aim of this study was to demonstrate how the severity of radiation damage in the case of bone marrow syndrome due to acute irradiation depends on the non-uniform irradiation of the body. We used the calculation method that involves the evaluation of organism mortality as a function of bone marrow cells colony survival vs dose for different radiation profiles. It was presumed that the probability of the death for the organism is the same for the same value of survival level of the bone marrow cells regardless of the dose distribution by mass of the organ. The dose of uniform irradiation that is equivalent to the dose for the L-th case of non-uniform irradiation is calculate based on the survival level of the total marrow cells. After that the probability of the death of the organism is estimated according to the dose response curve. Dose distribution in bone marrow of computational MIRD-5-type stylized model adult man for different geometries of exposure by point source of 137Cs was evaluated. Larger non-uniformity of the dose distribution in the bone marrow at the same dose in free air in the site of human location causes a greater probability of survival due to a greater proportion of bone marrow cells that have preserved the possibility of reproduction. The values of mean 50% lethal dose for cases of approximately uniform irradiation of the body surface (point source at a distance 10m) and sharply non-uniform irradiation (point source at a distance of 0.5 m) differ approximately by the factor of 1.7 – 2.5 depending on direction of irradiation. Additionally the values of conversion coefficients from the reading of an individual dosimeter to the value of an effective dose for various geometries of irradiation of emergency workers from the 137Cs point source were calculated. The average value of the conversion coefficient from personal dose to effective dose for the considered exposure situations is 0.7 Sv Cy-1 and the 90% confidence interval is 0.49 – 0.99 Sv Gy-1.

Publisher

SPRI of Radiation Hygiene Prof. PV Ramzaev

Subject

Radiology, Nuclear Medicine and imaging

Reference13 articles.

1. United Nations Scientific Committee on the Effects of Atomic Radiation. Sources and Effects of Ionizing Radiation. UNSCEAR 2008 Report to the General Assembly with Scientific Annexes. Volume II, Scientific Annexes C, D and E. New York, UN; 2011.

2. U.S. Department of Homeland Security. Technology Assessment and Roadmap for the Emergency Radiation Dose Assessment Program. UCRL-TR-215887. June, 2005.

3. National Council on Radiation Protection and Measurements. Management of terrorist events involving radioactive material. NCRP Report No. 138. Bethesda, Md: National Council on Radiation Protection and Measurements; 2001.

4. Avetisov GM, Darenskaya NG, Nelyubov AA. Biological effects of non-uniform radiation impacts. Moscow: Atomizdat; 1974.

5. Gozenbuk VL, Keirim-Markus IB. Dosimetric criteria for the severity of acute human irradiation. Moscow: Energoatomizdat; 1988.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3