Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”

Author:

Pyshkina M. D.1,Vasilyev A. V.2,Ekidin A. A.2,Nazarov E. I.2,Romanova M. A.3,Gurinovich V. I.4,Komar D. I.4,Kozhemyakin V. A.4

Affiliation:

1. Ural Federal University; Institute of Industrial Ecology, Ural Branch of the Russian Academy of Sciences

2. Institute of Industrial Ecology, Ural Branch of the Russian Academy of Sciences

3. Ural Federal University; Institute of Nuclear Materials

4. Scientific Production Unitary Enterprise «АТОМТЕХ»

Abstract

If the neutron fields at personnel workplaces differ from the neutron fields in which individual dosimeters are verified, there is a possibility of additional errors in the assessment of such dosimetric quantities as ambient dose equivalent, individual dose equivalent or effective dose. To take into account the energy distribution of the neutron radiation flux density and the geometry of the irradiation of workers, it is necessary to study the characteristics of the fields of neutron radiation at the workplaces of the personnel. In order to obtain conditionally true levels of personnel exposure to neutron radiation at nuclear facilities, studies of the energy and angular distribution of the neutron radiation flux density were carried out at the workplaces of the Institute of Reactor Materials JSC, Zarechny. The energy distribution of the neutron radiation flux density was obtained using an MKS-AT1117M multi-sphere dosimeter-radiometer with a BDKN-06 detection unit and a set of polyethylene spheres-moderators. The angular distribution of the neutron radiation flux density was estimated from the results of measurements of the accumulated dose of neutron radiation by individual thermoluminescent dosimeters placed on four vertical planes of a heterogeneous human phantom. The results of measurements of the energy and angular distribution of the neutron radiation flux density made it possible to estimate the conditionally true values of the ambient and individual dose equivalents. The calculated conventionally true values differ from the measured values from 0.7 to 8.9 times for the ambient dose equivalent and from 6 to 50 times for the individual dose equivalent. In order to reduce the error in assessing the effective dose of personnel using personal dosimeters, correction factors were determined. For different workplaces and types of personal dosimeters, correction factors are in the range of values from 0.02 to 0.16.

Publisher

SPRI of Radiation Hygiene Prof. PV Ramzaev

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Characteristics of neutron fields at pool-type research nuclear reactors;Radiatsionnaya Gygiena = Radiation Hygiene;2023-01-14

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3