Assessment of effective doses for fluoroscopy-guided balloon dilatation of benign esophageal strictures in pediatric medicine

Author:

Kapyrina Yu. N.1ORCID,Vodovatov A. V.2ORCID,Puzyrev V. G.1ORCID,Komissarov M. I.ORCID,Aleshin I. Yu.1ORCID,Golikov V. Yu.3,Orel V. I.1ORCID

Affiliation:

1. Saint-Petersburg State Pediatric Medical University of the Ministry of Health of the Russian Federation

2. Saint-Petersburg State Pediatric Medical University of the Ministry of Health of the Russian Federation; Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing

3. Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing

Abstract

Interventional examinations are associated with high levels of patient exposure per examination, which makes it particularly important to monitor individual patient doses and to assess radiation risks. The aim of this study was the assessment of effective doses for fluoroscopy-guided balloon dilatation of benign esophageal strictures, whichwasperformedonpediatricpatientsaged 1 to 2 yearsatthe Departmentof Radiosurgical Methodsof Diagnosis and Treatment of St. Petersburg State Pediatric Medical University. Patient exposure patterns were basedonourowndatacollection.    Thecalculationofeffectiveandorgandosesofpatientsnormalizedbythevalue of the dose area product measured during the study was carried out using PCXMC 2.0 software. The conversion coefficients from the dose area product to the effective dose were calculated using tissue weighting coefficients from the ICRP Publications 60 and 103 their values were 10.7 and 11.7 µSv/cGy cm2, respectively. The results of verification of the method indicated that the use of inappropriate conversion coefficients leads to an almost double underestimation of children’s effective doses. Differences in the values of conversion coefficients are significant and are explained by differences in voltage, source to image distance, and irradiation field size. A simplified model of patient exposure was proposed, which is described by a single irradiation field. The assessment of effective doses using multi-field and single-field irradiation model shows comparable results, which allows using the differentiated approach to the assessment of radiation doses of patients.

Publisher

SPRI of Radiation Hygiene Prof. PV Ramzaev

Subject

Radiology, Nuclear Medicine and imaging

Reference25 articles.

1. ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department. Ann ICRP. 2010 Dec;40(6): 1-102.

2. Scientific annex A: Evaluation of medical exposure to ionizing radiation The UNSCEAR 2020/2021 Report Volume I to the General Assembly (A/76/46). Official site UN SCEAR. Available from: https://css.unscear.org/unscear/uploads/documents/publications/UNSCEAR_2020_21_Annex-A.pdf (Accessed: 15.06.2023).

3. ISO/IEC 17025:2017(E) General requirements for the competence of testing and calibration laboratories; 2017.

4. EC. Radiation Protection no 180 Medical radiation exposure of the European population, Part , EU; 2014.

5. Ubeda C, Vano E, Miranda P, Figueroa X. Organ and effective doses detriment to paediatric patients undergoing multiple interventional cardiology procedures. Medical Physics. 2019;60: 182-187. doi: 10.1016/j.ejmp.2019.03.020.