A one-year cohort study of complications, continuation, and failure rates of postpartum TCu380A in Tanzania

Author:

Rwegoshora France John,Muganyizi Projestine Selestine,Kimario Grasiana Festus,Paul Ponsian Patrick,Makins Anita

Abstract

Abstract Background Less than 1% of married women in Tanzania use an Intrauterine Contraceptive Device (IUD) for contraception. An initiative by the International Federation of Gynecology and Obstetrics (FIGO) has been in progress since 2015 resulting in escalated method uptake in implementing hospitals. This study investigates failure rate, complications, and risk factors for one-year continuation of TCu380A IUD when used for immediate postpartum contraception under the initiative in Tanzania. Methodology A prospective cohort study of women who had TCu380A insertion within 48 h of delivery in 6 hospitals in Tanzania between 1st December 2017 and 18th April 2018 was conducted. Face to face post insertion interviews were made with 1114 clients before discharge and later through phone calls up to the beginning of 13th month postpartum. Postpartum Intrauterine Device (PPIUD) continuation status, complications, duration of time they stayed with the IUD and the currently used method if PPIUD was discontinued were enquired. The outcome variable was PPIUD continuation at one year of IUD insertion. Data were analyzed using Statistical Product and Service Solutions software (SPSS) for Windows version 20 (IBM SPSS Statistics, Chicago, IL, USA). Results In total 511(45.8%)clients had consented and availed to complete the one-year follow-up. Out of these, 440 still had IUD, giving a one-year continuation rate of 86.1%. Most (63%) IUD discontinuations occurred in the period between 7th week and 6 months of insertion. One-year method expulsion rate was 2.1%. There was one reported pregnancy that gives a method failure rate of about 2 per 1000. The independent risk factors in favor of method continuation at one year were absence of medical or social problem, being a youth (16–24 years), and delivery by Cesarean section. Conclusions The continuation rate when CuT380A is used for immediate postpartum contraception is high, with low complication and failure rates. Some medical and social factors are important for method continuation, hence the need to consider in training, counselling and advocacy.

Publisher

Springer Science and Business Media LLC

Subject

Obstetrics and Gynecology,Reproductive Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3