Cardiovascular magnetic resonance evaluation of aortic stenosis severity using single plane measurement of effective orifice area

Author:

Garcia Julio,Marrufo Oscar R,Rodriguez Alfredo O,Larose Eric,Pibarot Philippe,Kadem Lyes

Abstract

Abstract Background Transthoracic echocardiography (TTE) is the standard method for the evaluation of the severity of aortic stenosis (AS). Valve effective orifice area (EOA) measured by the continuity equation is one of the most frequently used stenotic indices. However, TTE measurement of aortic valve EOA is not feasible or not reliable in a significant proportion of patients. Cardiovascular magnetic resonance (CMR) has emerged as a non-invasive alternative to evaluate EOA using velocity measurements. The objectives of this study were: 1) to validate a new CMR method using jet shear layer detection (JSLD) based on acoustical source term (AST) concept to estimate the valve EOA; 2) to introduce a simplified JSLD method not requiring vorticity field derivation. Methods and results We performed an in vitro study where EOA was measured by CMR in 4 fixed stenoses (EOA = 0.48, 1.00, 1.38 and 2.11 cm2) under the same steady flow conditions (4-20 L/min). The in vivo study included eight (8) healthy subjects and 37 patients with mild to severe AS (0.72 cm2 ≤ EOA ≤ 1.71 cm2). All subjects underwent TTE and CMR examinations. EOA was determinated by TTE with the use of continuity equation method (TTECONT). For CMR estimation of EOA, we used 3 methods: 1) Continuity equation (CMRCONT); 2) Shear layer detection (CMRJSLD), which was computed from the velocity field of a single CMR velocity profile at the peak systolic phase; 3) Single plane velocity truncation (CMRSPVT), which is a simplified version of CMRJSLD method. There was a good agreement between the EOAs obtained in vitro by the different CMR methods and the EOA predicted from the potential flow theory. In the in vivo study, there was good correlation and concordance between the EOA measured by the TTECONT method versus those measured by each of the CMR methods: CMRCONT (r = 0.88), CMRJSLD (r = 0.93) and CMRSPVT (r = 0.93). The intra- and inter- observer variability of EOA measurements was 5 ± 5% and 9 ± 5% for TTECONT, 2 ± 1% and 7 ± 5% for CMRCONT, 7 ± 5% and 8 ± 7% for CMRJSLD, 1 ± 2% and 3 ± 2% for CMRSPVT. When repeating image acquisition, reproducibility of measurements was 10 ± 8% and 12 ± 5% for TTECONT, 9 ± 9% and 8 ± 8% for CMRCONT, 6 ± 5% and 7 ± 4% for CMRJSLD and 3 ± 2% and 2 ± 2% for CMRSPVT. Conclusion There was an excellent agreement between the EOA estimated by the CMRJSLD or CMRSPVT methods and: 1) the theoretical EOA in vitro, and 2) the TTECONT EOA in vivo. The CMRSPVT method was superior to the TTE and other CMR methods in terms of measurement variability. The novel CMR-based methods proposed in this study may be helpful to corroborate stenosis severity in patients for whom Doppler-echocardiography exam is inconclusive.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3