Author:
Boldt Julia,Leber Alexander W,Bonaventura Klaus,Sohns Christian,Stula Martin,Huppertz Alexander,Haverkamp Wilhelm,Dorenkamp Marc
Abstract
Abstract
Background
Recent studies have demonstrated a superior diagnostic accuracy of cardiovascular magnetic resonance (CMR) for the detection of coronary artery disease (CAD). We aimed to determine the comparative cost-effectiveness of CMR versus single-photon emission computed tomography (SPECT).
Methods
Based on Bayes’ theorem, a mathematical model was developed to compare the cost-effectiveness and utility of CMR with SPECT in patients with suspected CAD. Invasive coronary angiography served as the standard of reference. Effectiveness was defined as the accurate detection of CAD, and utility as the number of quality-adjusted life-years (QALYs) gained. Model input parameters were derived from the literature, and the cost analysis was conducted from a German health care payer’s perspective. Extensive sensitivity analyses were performed.
Results
Reimbursement fees represented only a minor fraction of the total costs incurred by a diagnostic strategy. Increases in the prevalence of CAD were generally associated with improved cost-effectiveness and decreased costs per utility unit (ΔQALY). By comparison, CMR was consistently more cost-effective than SPECT, and showed lower costs per QALY gained. Given a CAD prevalence of 0.50, CMR was associated with total costs of €6,120 for one patient correctly diagnosed as having CAD and with €2,246 per ΔQALY gained versus €7,065 and €2,931 for SPECT, respectively. Above a threshold value of CAD prevalence of 0.60, proceeding directly to invasive angiography was the most cost-effective approach.
Conclusions
In patients with low to intermediate CAD probabilities, CMR is more cost-effective than SPECT. Moreover, lower costs per utility unit indicate a superior clinical utility of CMR.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Cited by
50 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献