Abstract
Abstract
Background
Fetal hypoxia is one of the major causes of high perinatal morbidity and mortality rates. Doppler ultrasound tests such as cerebroplacental ratio (CPR) evaluation are commonly used to assess blood flow disturbances in placento-umbilical and feto-cerebral circulations. A low cerebroplacental ratio has been shown to be associated with an increased risk of stillbirth regardless of the gestation or fetal weight. We conducted this study to assess the fetal cerebroplacental ratio in prediction of adverse intrapartum and neonatal outcomes in a term, uncomplicated pregnancy to reduce fetal and neonatal morbidity and mortality.
Results
It was found that neonates with CPR ≤1.1 had significantly higher frequencies of cesarean delivery (CS) for intrapartum fetal compromise compared to those with CPR >1.1 (p=0.043). Neonates with CPR ≤1.1 had significantly lower Apgar score at 1 min and 5 min than those with CPR >1.1 (p=0.004) and (p=0.003), respectively. Neonates with CPR ≤1.1 had significantly higher rates of NICU admission than those with CPR <1.1 (p=0.004).
Conclusion
The cerebroplacental ratio shows the highest sensitivity in the prediction of fetal heart rate abnormalities and adverse neonatal outcome in uncomplicated pregnancies at term. The cerebroplacental ratio index is useful in clinical practice in antenatal monitoring of these women in order to select those at high risk of intra- and postpartum complications.
Publisher
Springer Science and Business Media LLC
Subject
Obstetrics and Gynecology,Reproductive Medicine
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献