Author:
Xia Ping,Zhang Shuangyi,Yu Jianwei,Ye Hui,Zhang Dong,Jiang Lei,Wang Zheng,Yin Daqiang
Abstract
Abstract
Background
Taste and odor problem in drinking water is one major concern for consumers and water supply. Exploring the odor characteristics and the major odor causing compounds in the source water is the base for odor control in drinking water treatment plant (WTP). In this study, focusing on a newly constructed reservoir with Huangpu River as the source water, the occurrence of typical odorants and their variations were first identified. Correspondingly, the removal behavior in an ozone/GAC advanced treatment process was investigated.
Results
The results indicated that 2-methylisoborneol (2-MIB), geosmin (GSM), and bis (2-chloroisopropyl) ether (BCIE) have major contribution to the musty/earthy and chemical/septic odors in the source water, respectively. Pre-ozonation alone (1 mg L−1) showed limited removal for 2-MIB and BCIE, at less than 30% and 20%, respectively, while combining with coagulation, sedimentation, and sand filtration, the removals were improved to higher than 50%. After post-ozonation, the desired removal was achieved at a 1.5 mg L−1 dosage with all the odorants decreased below the corresponding odor threshold concentrations (OTCs) in the effluents. Furthermore, at a 1 mg L−1 post-ozone addition, by combining with subsequent GAC process, the odor problem was solved as well.
Conclusion
To resolve the odor problem in the drinking water, the concentrations of the odorants at less than their OTCs need to be achieved. As 2-MIB and BCIE have low reactivity towards direct ozonation, a subsequent GAC is needed with a moderate dosage of post-ozonation (1 mg L−1). Thus, for the odor problem in the source water, the suggested operation is: 1 mg L−1 of pre-ozonation in combination with coagulation, sedimentation, and sand filtration, followed by a 1 mg L−1 dosage of post-ozonation and finished by a GAC process.
Funder
“125” Major Science and Technology Program for Water Pollution Control and Treatment
“135” Major Science and Technology Program for Water Pollution Control and Treatment
Shanghai Science and Technology Commission
Publisher
Springer Science and Business Media LLC
Reference68 articles.
1. Ahn H, Chae S, Kim S, Wang C, Summers RS (2007) Efficient taste and odour removal by water treatment plants around the Han River water supply system. Water Sci Technol 55(5):103–109
2. Antonopoulou M, Evgenidou E, Lambropoulou D, Konstantinou I (2014) A review on advanced oxidation processes for the removal of taste and odor compounds from aqueous media. Water Res 53:215–234
3. APHA, AWWA, WEF (2005) Standard Methods for the Examination of Water and Wastewater, twenty-first ed. APHA, Washington, DC
4. Atasi KZ, Chen T, Huddleston JI, Young CC, Suffet IH (1999) Factor screening for ozonating the taste- and odor-causing compounds in source water at Detroit, USA. Water Sci Technol 40(6):115–122
5. ATSDR (Agency for Toxic Substances and Disease Registry) (1999) Toxicological profile for ethylbenzene. Public Health Service, U.S. Department of Health and Human Services, Atlanta
Cited by
11 articles.
订阅此论文施引文献