Finite element analysis of coronoid prostheses with different fixation methods in the treatment of comminuted coronoid process fracture

Author:

Zhang Hailong,Lin Kun-Jhih,Liu Po-Yi,Lu YiORCID

Abstract

Abstract Background Comminuted fractures of the coronoid process significantly compromise the stability and function of the elbow joint. Reconstruction of the coronoid process with a prosthesis has been suggested as an alternative to restore the architecture. The purpose of this study was to investigate the strength and stability of various methods for the fixation of a coronoid prosthesis by finite element analysis. Materials and methods A coronoid prosthesis was designed based on the morphological information from computed tomography images acquired from 64 subjects in whom the top 40% of the coronoid process height was replaced. Four methods for the fixation of the prosthesis were suggested: (1) a double 2.0-mm fixation bolt, anterior to posterior; (2) a double 2.5-mm fixation bolt, anterior to posterior; (3) a single 4.0-mm fixation bolt, posterior to anterior; (4) a single 4.5-mm fixation bolt, posterior to anterior. The integrated prosthesis-bone constructs were analyzed via the finite element analysis of 10 simulated proximal ulna models with loading applied along the axis of the humerus and with three different elbow flexion angles (30°, 90°, and 130°). The maximum principal stress and the total deformation were quantified and compared. Results A coronoid prosthesis was developed. The maximum principal stress of the fixation bolts occurred around the neck of the fixation bolt. For a comparison of the strengths of the four fixation methods, the maximum principal stress was the lowest for fixation using a single 4.5-mm fixation bolt. The value of the maximum principal stress significantly decreased with increased elbow flexion angle for all fixation methods. The maximum deformation of the fixation bolts occurred at the head of the fixation bolt. For a comparison of the maximum deformations in the four fixation methods, the maximum deformation was the lowest for fixation using a single 4.5-mm fixation bolt. The value of the maximum deformation significantly decreased with increased elbow flexion angle for all fixation methods. Conclusions The present study suggested that fixation of a coronoid prosthesis with a single 4.5-mm fixation bolt from posterior to anterior is an excellent option in terms of the strength and stability. Level of Evidence Experimental study.

Funder

National Natural Science Foundation of China

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3