Abstract
Abstract
Background
Percutaneous iliosacral (IS) screw fixation and trans-iliac trans-sacral (TITS) screw fixation are clinically effective treatments of posterior pelvic sacroiliac fractures. In order to accurately assess the sacrum position relative to the pelvis, pelvic incidence (PI) is a commonly utilized radiographic parameter in sagittal view. This study aimed to investigate and compare the surgical outcomes and radiographic parameters of IS or TITS screw fixations for the treatment of posterior sacroiliac complex fractures with different PI values.
Materials and methods
The data on patients with posterior pelvic sacroiliac fractures who underwent percutaneous IS or TITS screw fixations, or both, at a single level I trauma center between January 2017 and June 2020 were reviewed. We documented the patient characteristics and fracture types, reviewed surgical records, and measured the radiographic parameters via plain films and multi-planar computed tomography (mpCT) images. Radiographic variations in PI, sacral slope, pelvic tilt, sacral dysmorphism, pelvic ring reduction quality, screw deviation angles, screw malposition grading, and iatrogenic complications were documented and analyzed.
Results
A total of 85 patients were included, and 65 IS and 70 TITS screws were accounted for. Patients were divided into two groups according to screw fixation method and further divided into four sub-groups based on baseline PI values. The PI cutoff values were 49.85° and 48.05° in the IS and TITS screw groups, respectively, according to receiver operating characteristic analysis and Youden's J statistic. Smaller PI values were significantly correlated with sacral dysmorphism (p = 0.027 and 0.003 in the IS and TITS screw groups, respectively). Patients with larger PI values were at a significantly increased risk of screw malposition in the TITS screw group (p = 0.049), with no association in the IS screw group. Logistic regression confirmed that a larger PI value was a significant risk factor for screw malposition in the TITS screw group (p = 0.010). The post-operative outcomes improved from poor/fair (at 6 months) to good/average (at 12 months) based on the Postel Merle d'Aubigné and Majeed scores, with no significant differences between subgroups.
Conclusions
Both percutaneous IS and TITS screw fixations are safe and effective treatments for posterior pelvic sacroiliac fractures. Due to the higher risk of screw malposition in patients with larger PI values, it is crucial to identify potential patients at risk when performing TITS screw fixation surgery.
Level of evidence:
Level III.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery