Study of a constrained finite element elbow prosthesis: the influence of the implant placement

Author:

Nalbone Lorenzo,Monac Francesco,Nalbone Luca,Ingrassia Tommaso,Ricotta Vito,Nigrelli Vincenzo,Ferruzza Massimo,Tarallo Luigi,Porcellini Giuseppe,Camarda LawrenceORCID

Abstract

Abstract Background The functional results of total elbow arthroplasty (TEA) are controversial and the medium- to long-term revision rates are relatively high. The aim of the present study was to analyze the stresses of TEA in its classic configuration, identify the areas of greatest stress in the prosthesis–bone–cement interface, and evaluate the most wearing working conditions. Materials and methods By means of a reverse engineering process and using a 3D laser scanner, CAD (computer-aided drafting) models of a constrained elbow prosthesis were acquired. These CAD models were developed and their elastic properties, resistance, and stresses were studied through finite element analysis (finite element method—FEM). The obtained 3D elbow-prosthesis model was then evaluated in cyclic flexion–extension movements (> 10 million cycles). We highlighted the configuration of the angle at which the highest stresses and the areas most at risk of implant mobilization develop. Finally, we performed a quantitative study of the stress state after varying the positioning of the stem of the ulnar component in the sagittal plane by ± 3°. Results The greatest von Mises stress state in the bone component for the 90° working configuration was 3.1635 MPa, which occurred in the most proximal portion of the humeral blade and in the proximal middle third of the shaft. At the ulnar level, peaks of 4.1763 MPa were recorded at the proximal coronoid/metaepiphysis level. The minimum elastic resistance and therefore the greatest stress states were recorded in the bone region at the apex of the ulnar stem (0.001967 MPa). The results of the analysis for the working configurations at 0° and 145° showed significant reductions in the stress states for both prosthetic components; similarly, varying the positioning of the ulnar component at 90° (− 3° in the sagittal plane, 0° in the frontal plane) resulted in better working conditions with a greater resulting developed force and a lower stress peak in the ulnar cement. Conclusion The areas of greatest stress occur in specific regions of the ulnar and humeral components at the bone–cement–prosthesis interface. The heaviest configuration in terms of stresses was when the elbow was flexed at 90°. Variations in the positioning in the sagittal plane can mechanically affect the movement, possibly resulting in longer survival of the implant. Level of evidence: 5

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Reference18 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3