Abstract
Abstract
Objectives
To validate the German version of OMPSQ (OMPSQ-G) for patients with chronic neck pain.
Results
After translating OMPSQ to German, we assessed the discriminant validity between patients and healthy adults. Convergent validity was assessed using Pearson’s correlation coefficients between domains of OMPSQ-G and the German version of neck disability index (NDI-G) and visual analogue scale (VAS) of neck pain intensity. Floor and ceiling effects, internal consistency, test–retest and relative reliability were assessed. Fifty patients with chronic neck pain (mean age, 43.6 years; 34 females) and 24 healthy adults (mean age, 50.4 years; 18 females) participated. Mann–Whitney U tests showed significant differences in OMPSQ scores between both groups at the baseline (z = − 4.6; p < 0.001) and second time point (z = − 4.8; p < 0.001). OMPSQ-G scores highly and moderately correlated with NDI-G (ρ = 0.70) and VAS (ρ = 0.41) scores, respectively. There were no floor or ceiling effects. Cronbach’s alpha was 0.94. OMPSQ-G showed high reliability (intraclass correlation 2.1: 0.93; standard error of measurement, 6.9; smallest detectable change, 20 points). The Bland–Altman plot indicated no systematic error. OMPSQ-G showed good validity and reliability in patients with neck pain.
Trial registration NCT02540343
Publisher
Springer Science and Business Media LLC
Subject
General Biochemistry, Genetics and Molecular Biology,General Medicine
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献