Applicability of commercial clinical chemistry test kits for horse serum

Author:

Megerssa Yoseph CherinetORCID,Gari Fikru Regassa,Woldemariyam Fanos Tadesse

Abstract

AbstractObjectiveValidation of a test method is critical for confirming that the test can generate accurate and precise data. Although commercial biochemical test kits exist there are no specific and validated commercial clinical chemistry test kits designed for horses. The aim of this study was to validate commercial clinical chemistry test kits designed for a human serum for use in horses.ResultsBlood samples were collected from 29 apparently healthy adult male horses and pooled serum was prepared. Validation comprises replication and recovery experiments. Total observable error (TEo), sigma (σ) metrics, and quality goal index (QGI) were used to support the validation studies. Intra- and inter-assay variability was 2.05% and 2.08%, 2.26% and 1.89%, 2.4% and 1.63%, for total cholesterol, urea and total protein, respectively; recovery was 99.46%, 97.32%, and 100.1% for total cholesterol, urea and total protein, respectively. TEo% for the specified analytes was within the total allowable error (TEa). All three analytes satisfied the recommended requirement (> 3σ). The QGI for urea, as it had below 6σ was 0.95 indicating imprecision and inaccuracy. The results endorse the suitability of the studied commercial test kits and illustrated the acceptance criteria for horse’s serum.

Funder

Addis Ababa University

Publisher

Springer Science and Business Media LLC

Subject

General Biochemistry, Genetics and Molecular Biology,General Medicine

Reference25 articles.

1. WHO Regional Committee for Africa Resolution AFR/RC58/R2: strengthening public health laboratories in the WHO African region: a critical need for disease control. In: WHO Regional Committee for Africa. Final Report: 58th Session of the WHO Regional Committee for Africa. WHO Regional Office for Africa, Brazzaville 2008; p. 11–13.

2. Rishniw Mark, Pion Paul D, Maher Tammy. The quality of veterinary in-clinic and reference laboratory biochemical testing. Vet Clin Pathol. 2012;41(1):92–109.

3. Cho MC, Kim SY, Jeong TD, Lee W, Chun S, Min WK. Statistical validation of reagent lot change in the clinical chemistry laboratory can confer insights on good clinical laboratory practice. Ann Clin Biochem. 2014;51(6):688–94.

4. Miller WG, Erek A, Cunningham TD, Oladipo O, Scott MG, Johnson RE. Commutability limitations influence quality control results with different reagent lots. Clin Chem. 2011;57(1):76–83.

5. Agarwal R, Chaturvedi S, Chhillar N, Goyal R, Pant I, Tripathi CB. Role of intervention on laboratory performance: evaluation of quality indicators in a Tertiary Care Hospital. Indian J Clin Biochem. 2012;27:61–8.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3