Abstract
AbstractThe insertion torque of a dental implant is an important indicator for the primary stability of dental implants. Thus, the preoperative prediction for the insertion torque is crucial to improve the success rate of implantation surgery. In this present research, an alternative method for prediction of implant torque was proposed. First, the mechanical model for the insertion torque was established based on an oblique cutting process. In the proposed mechanical model, three factors, including bone quality, implant geometry and surgical methods were considered in terms of bone-quality coefficients, chip load and insertion speeds, respectively. Then, the defined bone-quality coefficients for cancellous bone with the computed tomography (CT) value of 235–245, 345–355 and 415–425 Hu were obtained by a series of insertion experiments of IS and ITI implants. Finally, the insertion experiments of DIO implants were carried out to verify the accuracy of developed model. The predicted insertion torques calculated by the mechanical model were compared with those acquired by insertion experiments, with good agreement, the relative error being less than 15%. This method allows the insertion torque for different implant types to be quickly established and enhances prediction accuracy by considering the effects of implants’ geometries and surgical methods.
Funder
Science and Technology Development Program of Shandong Province
Taishan Scholars Program of Shandong Province
Publisher
Springer Science and Business Media LLC
Subject
Industrial and Manufacturing Engineering,Mechanical Engineering
Reference30 articles.
1. T Irinakis, C Wiebe. Initial torque stability of a new bone condensing dental implant. A cohort study of 140 consecutively placed implants. Journal of Oral Implantology, 2009, 35(6): 277–282.
2. A Nappo, C Rengo, G Pantaleo, et al. Influence of implant dimensions and position on implant stability: A prospective clinical study in maxilla using resonance frequency analysis. Applied Science-Basel, 2019, 9(5): 43–54.
3. M Aglietta, V Siciliano, M Zwahlen, et al. A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years. Clinical Oral Implants Research, 2009, 20(5): 441–451.
4. N Rizkallah, Fischer S, Kraut R A. Correlation between insertion torque and survival rates in immediately loaded implants in the maxilla: A retrospective study. Implant Dentistry, 2013, 22(3): 250–254.
5. M Akkocaoglu, M C Cehreli, I Tekdemir, et al. Primary stability of simultaneously placed dental implants in extraoral donor graft sites: A human cadaver study. Journal of the American Association of Oral & Maxillofacial Surgeon, 2007, 65(3): 400–407.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献