A rare case of retained sabot after close-range shotgun injury

Author:

Flippin J. AlfordORCID,Kishawi Sami,Braunstein Hannah,Lasinski Alaina M.

Abstract

Abstract Background Shotgun injuries are a relatively uncommon type of trauma, and therefore may present a challenge in management for trauma surgeons. This is particularly true in the case of surgeons unfamiliar with the unique characteristics of shotgun wounds and the mechanics of shotguns. In many cases, the shot pellets are the primary source of injury. However, a broad understanding of shotgun mechanics is important in recognizing alternative presentations. This article details a case of sabot (a stabilization device used with certain projectiles) retention after a close-range shotgun injury, reviews underlying shotgun mechanics, and discusses strategies for the detection and mitigation of these injuries. The aim of this case report is to increase awareness of and reduce the potential morbidity of close-range shotgun injuries. Case presentation A middle-aged female presented to the Emergency Department with wounds to her right hip and flank after suffering a shotgun injury. A contrast computed tomography scan demonstrated no evidence of hollow viscous or vascular injury, but was otherwise severely limited by scatter artifact from the numerous embedded pellets. The patient was admitted for wound care and discharged 2 days later with a clean wound bed and no evidence of tissue necrosis. Six days after injury, she reported an “unusual” smell associated with severe pain in her right hip wound. She was evaluated in clinic where examination revealed a retained foreign body, identified to be a shotgun shell sabot, which was removed in clinic. She presented again several days before scheduled follow-up with a persistent foul smell from her wound and was noted to have necrotic tissue at the base and margins of the wound that required hospital readmission for operative debridement and closure with negative pressure wound therapy. The patient had an uncomplicated recovery after surgical debridement. Conclusions Although shotgun sabot penetration and retention are rare, they are associated with significant morbidity. Sabot penetration should be considered if injury narrative, physical examination, or radiographic characteristics indicate a distance from shotgun to patient of less than 2 m. A high degree of suspicion is indicated at less than 1 m.

Publisher

Springer Science and Business Media LLC

Reference10 articles.

1. Malone J, Blaisdell FW, Wilson J. Wound ballistics. West J Med. 1977;127(1):49–54.

2. Adapted from: Coustan, D. "How Shotguns Work." 19 May 2005. HowStuffWorks.com. https://science.howstuffworks.com/shotgun.htm. Accessed 4 Mar 2021

3. Ordog GJ, Wasserberger J, Balasubramaniam S. Shotgun wound ballistics. J Trauma Inj Infect Crit Care. 1988;28(5):624–31. https://doi.org/10.1097/00005373-198805000-00011.

4. Esenkaya I. Removal of the wadding from the wound in shotgun-pellet injuries. Acta Orthop Traumatol Turc. 2002;36(3):236–41.

5. Clark JG, Shaw RC. Pulmonary cavitation and massive hemoptysis caused by an unsuspected intraparenchymal foreign body. Chest. 1980;78(5):776–7. https://doi.org/10.1378/chest.78.5.776.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3