SAFIR-I: first NEMA NU 4-2008-based performance characterization

Author:

Bebié PascalORCID,Lustermann Werner,Debus Jan,Ritzer Christian,Dissertori Günther,Weber Bruno

Abstract

Abstract Background Small Animal Fast Insert for MRI detector I (SAFIR-I) is a novel Positron Emission Tomography insert for a $$7\,\hbox {T}$$ 7 T Bruker BioSpec 70/30 Ultra Shield Refrigerated Magnetic Resonance Imaging (MRI) system. It facilitates truly simultaneous quantitative imaging in mice and rats at injected activities as high as $$500\,\hbox {MBq}$$ 500 MBq . Exploitation of the resulting high count rates enables quick image formation at few seconds per frame. In this investigation, key performance parameters of SAFIR-I have been determined according to the evaluations outlined in the National Electrical Manufacturers Association (NEMA) Standards Publication NU 4-2008 (NEMA-NU4) protocol. Results Using an energy window of 391 to $$601\,\hbox {keV}$$ 601 keV and a Coincidence Timing Window of $$500\,\hbox {ps}$$ 500 ps , the following performance was observed: The average spatial resolution at $$5\,\hbox {mm}$$ 5 mm radial offset (Full Width at Half Maximum) is $$2.54\,\hbox {mm}$$ 2.54 mm when using Filtered Backprojection, 3D Reprojection reconstruction. For the mouse- and rat-like phantoms, the maximal Noise-Equivalent Count Rates (NECRs) are $$1368\,\hbox {kcps}$$ 1368 kcps at the highest tested average effective concentration of $$14.7\,\hbox {MBq}\,\hbox {cc}^{-1}$$ 14.7 MBq cc - 1 , and $$713\,\hbox {kcps}$$ 713 kcps at the highest tested average effective concentration of $$1.72\,\hbox {MBq}\,\hbox {cc}^{-1}$$ 1.72 MBq cc - 1 , respectively. The NECR peak is not yet reached for either of these cases. The peak sensitivity is $$1.46\,\%$$ 1.46 % . The Image Quality phantom uniformity standard deviation is $$4.8\,\%$$ 4.8 % . The Recovery Coefficient for the $$5\,\hbox {mm}$$ 5 mm rod is $$(1.08 \pm 0.10)$$ ( 1.08 ± 0.10 ) . The Spill-Over Ratios are $$(0.22 \pm 0.03)$$ ( 0.22 ± 0.03 ) and $$(0.22 \pm 0.02)$$ ( 0.22 ± 0.02 ) , for the water- and air-filled cylinder, respectively. An accuracy of $$4.3\,\%$$ 4.3 % was achieved for the quantitative calibration of reconstructed voxel values. Conclusions The measured performance parameters indicate that the various design goals have been achieved. SAFIR-I offers excellent performance, especially at the high activities it was designed for. This facilitates planned experiments with fast tracer kinetics in small animals. Ways to potentially improve performance can still be explored. Simultaneously, further performance gains can be expected for a forthcoming insert featuring 2.7 times longer axial coverage named Small Animal Fast Insert for MRI detector II (SAFIR-II).

Funder

ETH Zürich Foundation

University of Zurich

Eidgenössische Technische Hochschule Zürich

Swiss Federal Institute of Technology Zurich

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3