The determination of the optimal threshold on measurement of thyroid volume using quantitative SPECT/CT for Graves' hyperthyroidism

Author:

Gong Chengpeng,Zhang Yajing,Feng Fei,Hu Mengmeng,Li Kun,Pi Rundong,Shu Hua,Tang Rongmei,Wang Xiaoli,Tan Shilin,Hu FanORCID,Hu Jia

Abstract

Abstract Purpose To investigate the optimal threshold for measuring thyroid volume in patients with Grave's hyperthyroidism (GH) by SPECT/CT. Materials and methods A 53 mL butterfly-shaped hollow container made of two 45-degree transparent elbows was put into a NEMA IEC phantom tank. The butterfly-shaped container and the tank were then filled with Na99mTcO4 of different radioactive concentrations, respectively, which could simulate thyroid gland with GH by different target-to-background ratios (T/B) (200:1, 600:1, 1000:1). The different T/B of planar imaging and SPECT/CT were acquired by a Discovery NM/CT 670 Pro SPECT/CT. With Thyroid software (Version 4.0) of GE-Xeleris workstation, the region of the thyroid gland in planar imaging was delineated. The thyroid area and average long diameter of both lobes were substituted into the Allen formula to calculate the thyroid volume. The calculation error was compared with the actual volume. Q-Metrix software was used to perform CT-based attenuation correction, scatter correction, resolution recovery. Ordered-subsets expectation maximization was used to reconstruct SPECT data. 20%, 25%, 30%, 40%, 50%, 60% thresholds were selected to automatically delineate the volume of interest and compared with the real volume, which determinated the optimal threshold. We measured the thyroid volume of 40 GH patients using the threshold and compared the volumes obtained by planar imaging and ultrasound three-dimensional. The differences of the volumes with different T/B and thresholds were compared by the ANOVA and least significant difference t test. The volumes delineated by SPECT/CT were evaluated using ANOVA, least significant difference t test, correlation analysis and, linear regression and Bland–Altman concordance test plot. The differences and consistency of thyroid volume were compared among the above three methods. Results There was no significant difference in the results between different T/B models (P > 0.05). The thyroid volume calculated by the planar imaging formula method was higher than the real volume, with an average overestimation of 22.81%. The volumes delineated by SPECT/CT threshold automatically decreased while the threshold increased. There were significant differences between groups with different thresholds (P < 0.001). With an average error of 3.73%, the thyroid volume analyzed by the threshold of 25% was close to the results of ultrasound measurement (P > 0.05). Thyroid volume measured by planar imaging method was significantly higher than ultrasound and SPECT/CT threshold automatic delineation method (P < 0.05). The agreement between the SPECT/CT 25% threshold and ultrasound (r = 0.956, b = 0.961) was better than that between the planar imaging and ultrasound (r = 0.590, b = 0.574). The Bland–Altman plot also showed that the thyroid volume measured by the 25% threshold automatic delineation method was in good agreement with the ultrasound measurement. Conclusions The T/B has no effect on the measurement of thyroid volume in GH patients; planar imaging method can significantly overestimate thyroid volume in GH patients, and 25% threshold automatic delineation method can obtain more accurate thyroid volume in GH patients.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3