A population-based method to determine the time-integrated activity in molecular radiotherapy

Author:

Hardiansyah Deni,Riana Ade,Kletting Peter,Zaid Nouran R. R.,Eiber Matthias,Pawiro Supriyanto A.,Beer Ambros J.,Glatting GerhardORCID

Abstract

Abstract Background The calculation of time-integrated activities (TIAs) for tumours and organs is required for dosimetry in molecular radiotherapy. The accuracy of the calculated TIAs is highly dependent on the chosen fit function. Selection of an adequate function is therefore of high importance. However, model (i.e. function) selection works more accurately when more biokinetic data are available than are usually obtained in a single patient. In this retrospective analysis, we therefore developed a method for population-based model selection that can be used for the determination of individual time-integrated activities (TIAs). The method is demonstrated at an example of [177Lu]Lu-PSMA-I&T kidneys biokinetics. It is based on population fitting and is specifically advantageous for cases with a low number of available biokinetic data per patient. Methods Renal biokinetics of [177Lu]Lu-PSMA-I&T from thirteen patients with metastatic castration-resistant prostate cancer acquired by planar imaging were used. Twenty exponential functions were derived from various parameterizations of mono- and bi-exponential functions. The parameters of the functions were fitted (with different combinations of shared and individual parameters) to the biokinetic data of all patients. The goodness of fits were assumed as acceptable based on visual inspection of the fitted curves and coefficients of variation CVs < 50%. The Akaike weight (based on the corrected Akaike Information Criterion) was used to select the fit function most supported by the data from the set of functions with acceptable goodness of fit. Results The function $$A_{1} { }\beta { }e^{{ - \left( {\lambda_{1} + \lambda_{{{\text{phys}}}} } \right)t}} + A_{1} { }\left( {1 - \beta } \right){ }e^{{ - \left( {\lambda_{{{\text{phys}}}} } \right)t}}$$ A 1 β e - λ 1 + λ phys t + A 1 1 - β e - λ phys t with shared parameter $$\beta$$ β was selected as the function most supported by the data with an Akaike weight of 97%. Parameters $$A_{1}$$ A 1 and $$\lambda_{1}$$ λ 1 were fitted individually for every patient while parameter $$\beta { }$$ β was fitted as a shared parameter in the population yielding a value of 0.9632 ± 0.0037. Conclusions The presented population-based model selection allows for a higher number of parameters of investigated fit functions which leads to better fits. It also reduces the uncertainty of the obtained Akaike weights and the selected best fit function based on them. The use of the population-determined shared parameter for future patients allows the fitting of more appropriate functions also for patients for whom only a low number of individual data are available.

Funder

universitas indonesia

deutscher akademischer austauschdienst

Universität Ulm

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3