3D printed anthropomorphic left ventricular myocardial phantom for nuclear medicine imaging applications

Author:

Kiss JanosORCID,Balkay Laszlo,Kukuts Kornel,Miko Marton,Forgacs Attila,Trencsenyi Gyorgy,Krizsan Aron K.

Abstract

Abstract Background Anthropomorphic torso phantoms, including a cardiac insert, are frequently used to investigate the imaging performance of SPECT and PET systems. These phantom solutions are generally featuring a simple anatomical representation of the heart. 3D printing technology paves the way to create cardiac phantoms with more complex volume definition. This study aimed to describe how a fillable left ventricular myocardium (LVm) phantom can be manufactured using geometry extracted from a patient image. Methods The LVm of a healthy subject was segmented from 18F-FDG attenuation corrected PET image set. Two types of phantoms were created and 3D printed using polyethylene terephthalate glycol (PETG) material: one representing the original healthy LVm, and the other mimicking myocardium with a perfusion defect. The accuracy of the LVm phantom production was investigated by high-resolution CT scanning of 3 identical replicas. 99mTc SPECT acquisitions using local cardiac protocol were performed, without additional scattering media (“in air” measurements) for both phantom types. Furthermore, the healthy LVm phantom was inserted in the commercially available DataSpectrum Anthropomorphic Torso Phantom (“in torso” measurement) and measured with hot background and hot liver insert. Results Phantoms were easy to fill without any air-bubbles or leakage, were found to be reproducible and fully compatible with the torso phantom. Seventeen segments polar map analysis of the "in air” measurements revealed that a significant deficit in the distribution appeared where it was expected. 59% of polar map segments had less than 5% deviation for the "in torso” and "in air” measurement comparison. Excluding the deficit area, neither comparison had more than a 12.4% deviation. All the three polar maps showed similar apex and apical region values for all configurations. Conclusions Fillable anthropomorphic 3D printed phantom of LVm can be produced with high precision and reproducibility. The 3D printed LVm phantoms were found to be suitable for SPECT image quality tests during different imaging scenarios. The flexibility of the 3D printing process presented in this study provides scalable and anthropomorphic image quality phantoms in nuclear cardiology imaging.

Funder

Innovációs és Technológiai Minisztérium

University of Debrecen

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3