Towards accurate 177Lu SPECT activity quantification and standardization using lesion-to-background voxel ratio

Author:

Raskin Stanislav,Gamliel Dan,Abookasis David,Ben-Haim Simona,Chicheportiche AlexandreORCID

Abstract

Abstract Background Conventional calibration of the gamma camera consists of the calculation of calibration factors (CFs) (ratio of counts/cc and true concentration activity) as the function of the volume of interest (VOI). However, such method shows inconsistent results when the background activity varies. The aim of the present study was to propose a new calibration method by considering the sphere-to-background counts/voxel ratio (SBVR) in addition to the VOI for CFs calculation. A PET cylindrical flood phantom, a NEMA IQ body phantom, a Data spectrum Torso Phantom (ECT/TOR/P) and a LK-S Kyoto Liver/Kidney phantom were used. The NEMA IQ phantom was used to calibrate the camera and to produce CFs for the different spheres volumes and for varying sphere-to-background activity ratios. The spheres were filled with a uniform activity concentration of 177Lu, while the background was first filled with cold water and activity was added between each SPECT scan. SPECT imaging was performed for 30-s, 20-s, and 10-s exposure per view. The calculated CFs were expressed as function of the sphere volume and SBVR. The obtained CFs were validated for an additional NEMA IQ acquisition with different activities in spheres and background and for the Torso and Liver/Kidney phantoms with inserted NEMA IQ spheres. The quantification accuracy was compared with the conventional method not taking SBVR into consideration. Results The relative errors in quantification using the NEMA IQ phantom with the new calibration method were 0.16%, 5.77%, 9.34% for the large, medium and small sphere, respectively, for a time per view of 30-s. The conventional calibration method gave errors of 3.65%, 6.65%, 30.28% for 30-s. The LK-S Kyoto Liver/Kidney Phantom resulted in quantification errors of 3.40%, 2.14%, 11.18% for the large, medium and small spheres, respectively, for 30-s; compared to 11.31%, 17.54%, 14.43% for 30-s, respectively, for the conventional method. Similar results were obtained for shorter acquisitions times with 20-s and 10-s time per view. Conclusion These results suggest that SBVR allows to improve quantification accuracy. The shorter time-per-view acquisitions had similar relative differences compared to the full-time acquisition which allows shorter imaging times with 177Lu and improved patient comfort. The SBVR method is simple to set up and can be proposed for standardization.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP