A novel rotation method with variable-angle anterior probe for correcting the depth of the kidney to optimize renal dynamic imaging

Author:

Wei Hua,Han Ke,Wu Jiaojiao,Hu Guang,Wu Zhifang,Wang Hongliang,Guo Xiaoshan,Hou Yansong,Wang Rui,Li SijinORCID

Abstract

Abstract Purpose We aimed to investigate the effect and significance of the rotation method with variable-angle anterior probe corrected for the depth of two kidneys on the determination of glomerular filtration rate (GFR) in total and single kidneys by the renal dynamic imaging Gates method. Methods Seventy-two patients who underwent dynamic renal imaging by the rotation method and abdominal CT in our hospital were collected in the present study. CT scanning, rotation method, Tonnesen's formula, and Li-Qian's formula were compared in terms of the depth of two kidneys, the depth difference between the two kidneys, and the total renal and single GFR obtained by substituting the renal depth values into Gates' formula. Results The depth of kidneys and GFR: Compared to CT, Tonnesen's formula significantly underestimated the depth of both kidneys and the total and single renal GFR (P < 0.05). No significant differences were found in the depth of both kidneys and the total and single renal GFR between Li-Qian's formula and the rotation method (P > 0.05), with a strong agreement and with the least bias in the values measured by the rotation method. ②Renal depth difference: Compared to CT, Tonnesen's formula and Li-Qian's formula underestimated the difference in depth between the two kidneys (P < 0.05). None of the differences were statistically significant based on the rotation method (P > 0.05). The depth difference was positively correlated with the resulting changes in single renal function (|R(CT)-R(Li-Qian)|) and (|R(Rotation)-R(Li-Qian)|) (r = 0.881, 0.641, P < 0.001). As the depth difference increased, Li-Qian's formula could not visualize changes in single renal function accurately. In contrast, the accuracy of the rotation method in assessing single renal function remains unaffected. Conclusion The rotation method obtains an accurate depth and depth difference between the two kidneys without additional CT radiation, enhancing the accuracy of the Gates method for determining total and single renal GFR. Trial registration Medical Ethics Committee of First Hospital of Shanxi Medical University, 2021BAL0146. Registered 12 January 2021.

Funder

Natural Science Foundation of Shanxi Province

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3