177Lu-DOTA-0-Tyr3-octreotate infusion modeling for real-time detection and characterization of extravasation during PRRT

Author:

Mazzara Christophe,Salvadori JulienORCID,Ritzenthaler Florian,Martin Simon,Porot Clémence,Imperiale Alessio

Abstract

Abstract Purpose Given the recent and rapid development of peptide receptor radionuclide therapy (PRRT), increasing emphasis should be placed on the early identification and quantification of therapeutic radiopharmaceutical (thRPM) extravasation during intravenous administration. Herein, we provide an analytical model of 177Lu-DOTA0-Tyr3-octreotate (Lutathera®) infusion for real-time detection and characterization of thRPM extravasation. Methods For 33 Lutathera®-based PRRT procedures using the gravity infusion method, equivalent dose rates (EDRs) were monitored at the patient’s arm. Models of flow dynamics for nonextravasated and extravasated infusions were elaborated and compared to experimental data through an equivalent dose rate calibration. Nonextravasated infusion was modeled by assuming constant volume dilution of 177Lu activity concentration in the vial and Poiseuille-like laminar flow through the tubing and patient vein. Extravasated infusions were modeled according to their onset times by considering elliptically shaped extravasation region with different aspect ratios. Results Over the 33 procedures, the peak of the median EDR was reached 14 min after the start of the infusion with a value of 450 µSv h−1. On the basis of experimental measurements, 1 mSv h−1 was considered the empirical threshold for Lutathera® extravasation requiring cessation of the infusion and start again with a new route of injection. According to our model, the concentration of extravascular activity was directly related to the time of extravasation onset and its duration, a finding inherent in the gravity infusion method. This result should be considered when planning therapeutic strategy in the case of RPM extravasation because the local absorbed dose for β-emitters is closely linked to activity concentration. For selected EDR values, charts of extravasated activity, volume, and activity concentration were computed for extravasation characterization. Conclusion We proposed an analytical model of Lutathera® infusion and extravasation (gravity method) based on EDR monitoring. This approach could be useful for the early detection of thRPM extravasation and for the real-time assessment of activity concentration and volume accumulation in the extravascular medium.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3