Inter-observer variability of 90Y PET/CT dosimetry in hepatocellular carcinoma after glass microspheres transarterial radioembolization

Author:

Meyers Nicolas,Jadoul Alexandre,Bernard Claire,Delwaide Jean,Lamproye Anne,Detry Olivier,Honoré Pierre,Gerard Laurent,Hustinx Roland

Abstract

Abstract Introduction Strong correlation has been demonstrated between tumor dose and response and between healthy liver dose and side effects. Individualized dosimetry is increasingly recommended in the current clinical routine. However, hepatic and tumor segmentations could be complex in some cases. The aim of this study is to assess the reproducibility of the tumoral and non-tumoral liver dosimetry in selective internal radiation therapy (SIRT). Material and methods Twenty-three patients with hepatocellular carcinoma (HCC) who underwent SIRT with glass microspheres were retrospectively included in the study. Tumor (TV) and total liver volumes (TLV), and mean absorbed doses in tumoral liver (TD) and non-tumoral liver (THLD) were determined on the 90Y PET/CT studies using Simplicit90YTM software, by three independent observers. Dosimetry datasets were obtained by a medical physicist helped by a nuclear medicine (NM) physician with 10 years of experience (A), by a NM physician with 4-year experience (B), and by a resident who first performed 10 dosimetry assessments as a training (C). Inter-observer agreement was evaluated using intra-class correlation coefficients (ICC), coefficients of variation (CV), Bland-Altman plots, and reproducibility coefficient (RDC). Results A strong agreement was observed between all three readers for estimating TLV (ICC 0.98) and THLD (ICC 0.97). Agreement was lower for TV delineation (ICC 0.94) and particularly for TD (ICC 0.73), especially for the highest values. Regarding TD, the CV (%) was 26.5, 26.9, and 20.2 between observers A and B, A and C, and B and C, respectively, and the RDC was 1.5. Regarding THLD, it was 8.5, 12.7, and 9.4, and the RDC was 1.3. Conclusion Using a standardized methodology, and regardless of the different experiences of the observers, the estimation of THLD is highly reproducible. Although the reproducibility of the assessment of tumor irradiation is overall quite high, large variations may be observed in a limited number of patients.

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3