Aortic valve imaging using 18F-sodium fluoride: impact of triple motion correction

Author:

Lassen Martin Lyngby,Tzolos Evangelos,Massera Daniele,Cadet Sebastien,Bing Rong,Kwiecinski Jacek,Dey Damini,Berman Daniel S.,Dweck Marc R.,Newby David E.,Slomka Piotr J.ORCID

Abstract

Abstract Background Current 18F-NaF assessments of aortic valve microcalcification using 18F-NaF PET/CT are based on evaluations of end-diastolic or cardiac motion-corrected (ECG-MC) images, which are affected by both patient and respiratory motion. We aimed to test the impact of employing a triple motion correction technique (3 × MC), including cardiorespiratory and gross patient motion, on quantitative and qualitative measurements. Materials and methods Fourteen patients with aortic stenosis underwent two repeat 30-min PET aortic valve scans within (29 ± 24) days. We considered three different image reconstruction protocols; an end-diastolic reconstruction protocol (standard) utilizing 25% of the acquired data, an ECG-gated (four ECG gates) reconstruction (ECG-MC), and a triple motion-corrected (3 × MC) dataset which corrects for both cardiorespiratory and patient motion. All datasets were compared to aortic valve calcification scores (AVCS), using the Agatston method, obtained from CT scans using correlation plots. We report SUVmax values measured in the aortic valve and maximum target-to-background ratios (TBRmax) values after correcting for blood pool activity. Results Compared to standard and ECG-MC reconstructions, increases in both SUVmax and TBRmax were observed following 3 × MC (SUVmax: Standard = 2.8 ± 0.7, ECG-MC = 2.6 ± 0.6, and 3 × MC = 3.3 ± 0.9; TBRmax: Standard = 2.7 ± 0.7, ECG-MC = 2.5 ± 0.6, and 3 × MC = 3.3 ± 1.2, all p values ≤ 0.05). 3 × MC had improved correlations (R2 value) to the AVCS when compared to the standard methods (SUVmax: Standard = 0.10, ECG-MC = 0.10, and 3 × MC = 0.20; TBRmax: Standard = 0.20, ECG-MC = 0.28, and 3 × MC = 0.46). Conclusion 3 × MC improves the correlation between the AVCS and SUVmax and TBRmax and should be considered in PET studies of aortic valves using 18F-NaF.

Funder

National Heart, Lung, and Blood Institute

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3