Simultaneous 166Ho/99mTc dual-isotope SPECT with Monte Carlo-based downscatter correction for automatic liver dosimetry in radioembolization

Author:

van Rooij R.ORCID,Braat A. J. A. T.,de Jong H. W. A. M.,Lam M. G. E. H.

Abstract

Abstract Background Intrahepatic dosimetry is paramount to optimize radioembolization treatment accuracy using radioactive holmium-166 microspheres (166Ho). This requires a practical protocol that combines quantitative imaging of microsphere distribution with automated and robust delineation of the volumes of interest. To this end, we propose a dual isotope single photon emission computed tomography (SPECT) protocol based on 166Ho therapeutic microspheres and technetium-99 m (99mTc) stannous phytate, which accumulates in healthy liver tissue. This protocol may allow accurate and automatic estimation of tumor-absorbed dose and healthy liver-absorbed dose. The current study focuses on a Monte Carlo-based reconstruction framework that inherently corrects for scatter crosstalk between the 166Ho and 99mTc imaging. To demonstrate the feasibility of the method, it is evaluated with realistic phantom experiments and patient data. Methods The Utrecht Monte Carlo System (UMCS) was extended to include detailed modeling of crosstalk interactions between 99mTc and 166Ho. First, 99mTc images were reconstructed including energy window-based corrections for 166Ho downscatter. Next, 99mTc downscatter in the 81-keV 166Ho window was Monte Carlo simulated to allow quantitative reconstruction of the 166Ho images. The accuracy of the 99mTc-downscatter modeling was evaluated by comparing measurements with simulations. In addition, the ratio between 99mTc and 166Ho yielding the best 166Ho dose estimates was established and the quantitative accuracy was reported. Results Given the same level of activity, 99mTc contributes twice as many counts to the 81-keV window than 166Ho, and four times as many counts to the 140-keV window, applying a 166Ho/99mTc ratio of 5:1 yielded a high accuracy in both 166Ho and 99mTc reconstruction. Phantom experiments revealed that the accuracy of quantitative 166Ho activity recovery was reduced by 10% due to the presence of 99mTc. Twenty iterations (8 subsets) of the SPECT/CT reconstructions were considered feasible for clinical practice. Applicability of the proposed protocol was shown in a proof-of-concept case. Conclusion A novel 166Ho/99mTc dual-isotope protocol for automatic dosimetry compensates accurately for downscatter and allows for the addition of 99mTc without compromising 166Ho SPECT image quality.

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3