Management of failed UKA to TKA: conventional versus robotic-assisted conversion technique

Author:

Yun Andrew G.,Qutami Marilena,Chen Chang-Hwa Mary,Pasko Kory B. DylanORCID

Abstract

Abstract Background Failure of unicompartmental knee arthroplasty (UKA) is a distressing and technically challenging complication. Conventional conversion techniques (CCT) with rods and jigs have produced varying results. A robotic-assisted conversion technique (RCT) is an unexplored, though possibly advantageous, alternative. We compare our reconstructive outcomes between conventional and robotic methods in the management of failed UKA. Methods Thirty-four patients with a failed UKA were retrospectively reviewed. Patients underwent conversion total knee arthroplasty (TKA) with either a CCT or RCT. Seventeen patients were included in each group. All procedures were done by a single surgeon at a single institution, with a mean time to follow-up of 3.6 years (range, 1 to 12). The primary outcome measures were the need for augments and polyethylene thickness. Secondary outcome measures were complications, need for revision, estimated blood loss (EBL), length of stay, and operative time. Results The mean polyethylene thickness was 12 mm (range, 9 to 15) in the CCT group and 10 mm (range, 9 to 14) in the RCT groups, with no statistical difference between the two groups (P = 0.07). A statistically significant difference, however, was present in the use of augments. In the CCT group, five out of 17 knees required augments, whereas none of the 17 knees in the RCT group required augments (P = 0.04). Procedurally, robotic-assisted surgery progressed uneventfully, even with metal artifact noted on the preoperative computerized tomography (CT) scans. Computer mapping of the residual bone surface after implant removal was a helpful guide in minimizing resection depth. No further revisions or reoperations were performed in either group. Conclusions Robotic-assisted conversion TKA is technically feasible and potentially advantageous. In the absence of normal anatomic landmarks to guide conventional methods, the preoperative CT scans were unexpectedly helpful in establishing mechanical alignment and resection depth. In this limited series, RCT does not seem to be inferior to CCT. Further investigation of outcomes is warranted.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3