Abstract
Abstract
Background
Preoperative radiographic templating for total knee arthroplasty (TKA) has been shown to be inaccurate. Patient demographic data, such as gender, height, weight, age, and race, may be more predictive of implanted component size in TKA.
Materials and methods
A multivariate linear regression model was designed to predict implanted femoral and tibial component size using demographic data along a consecutive series of 201 patients undergoing index TKA. Traditional, two-dimensional, radiographic templating was compared to demographic-based regression predictions on a prospective 181 consecutive patients undergoing index TKA in their ability to accurately predict intraoperative implanted sizes. Surgeons were blinded of any predictions.
Results
Patient gender, height, weight, age, and ethnicity/race were predictive of implanted TKA component size. The regression model more accurately predicted implanted component size compared to radiographically templated sizes for both the femoral (P = 0.04) and tibial (P < 0.01) components. The regression model exactly predicted femoral and tibial component sizes in 43.7 and 43.7% of cases, was within one size 90.1 and 95.6% of the time, and was within two sizes in every case. Radiographic templating exactly predicted 35.4 and 36.5% of cases, was within one size 86.2 and 85.1% of the time, and varied up to four sizes for both the femoral and tibial components. The regression model averaged within 0.66 and 0.61 sizes, versus 0.81 and 0.81 sizes for radiographic templating for femoral and tibial components.
Conclusions
A demographic-based regression model was created based on patient-specific demographic data to predict femoral and tibial TKA component sizes. In a prospective patient series, the regression model more accurately and precisely predicted implanted component sizes compared to radiographic templating.
Level of evidence
Prospective cohort, level II.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Reference25 articles.
1. Aslam N, Lo S, Nagarajah K, Pasapula C, Akmal M (2004) Reliability of preoperative templating in total knee arthroplasty. Acta Orthop Belg 70(6):560–564
2. The B, Diercks RL, Van Ooijen PM, Van Horn JR (2005) Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop 76(1):78–84
3. Howcroft DW, Fehily MJ, Peck C, Fox A, Dillon B, Johnson DS (2006) The role of preoperative templating in total knee arthroplasty: comparison of three prostheses. Knee. 13(6):427–429
4. Specht LM, Levitz S, Iorio R, Healy WL, Tilzey JF (2007) A comparison of acetate and digital templating for total knee arthroplasty. Clin Orthop Relat Res 464:179–183
5. Unnanuntana A, Arunakul M, Unnanuntana A (2007) The accuracy of preoperative templating in total knee arthroplasty. J Med Assoc Thail 90(11):2338–2343
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献