Abstract Introduction Revision knee arthroplasty presents a number of challenges, including management of bone loss. The goal in managing moderate to large bone defects is fixation that is sufficient enough to allow early weight-bearing. The purpose of this study was to describe the surgical technique and clinical and radiographic outcomes of patients treated with porous tantalum metaphyseal cones in combination with long uncemented diaphyseal-engaging stems to manage tibial bone loss in revision total knee arthroplasty (TKA). Materials and methods Thirty-six aseptic revision TKAs were performed at our institution between 2016 and 2019 by two senior authors. A single trabecular metal tantalum cone combined with a long (100 or 155 mm) press fit, diaphyseal-engaging stem was used in all cases to reconstruct metaphyseal bone defects and to augment tibial fixation. Cemented stems were excluded. The tibiofemoral angle was measured along the tibial and femoral shaft axes on the weight-bearing anteroposterior radiograph at final follow-up (range 15–56 months). All clinical and surgical complications, reoperations, and revisions of any component were recorded. Survivorship free of revision was evaluated at the time of the latest follow-up. Results The mean Knee Society Score (KSS) and Knee Society Function Score (KSS-F) improved significantly from 29.7 points preoperatively (range 11–54 points) to 86 points (range 43–99 points) and from 20.4 points preoperatively (range 0–55 points) to 72.3 points (range 30–90 points) (p < 0.05), respectively. Eleven tibial constructs (30.5%) had incomplete, nonprogressive radiolucent lines (≤ 2 mm). All tibial cones demonstrated osteointegration. One patient underwent a full revision for periprosthetic joint infection, and survivorship free of any component revision was 91.7% at final follow-up. Conclusions Hybrid fixation with uncemented diaphyseal-engaging stems and porous tantalum metaphyseal cones resulted in radiographic lack of osteolysis, good clinical outcomes, and survivorship of 91.7% at a median follow-up of 33 months when considering all-cause revision as the endpoint.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3