Author:
Foster Madison,Presseau Justin,McCleary Nicola,Carroll Kelly,McIntyre Lauralyn,Hutton Brian,Brehaut Jamie
Abstract
Abstract
Background
Laboratory tests and transfusions are sometimes ordered inappropriately, particularly in the critical care setting, which sees frequent use of both. Audit and Feedback (A&F) is a potentially useful intervention for modifying healthcare provider behaviors, but its application to the complex, team-based environment of critical care is not well understood. We conducted a systematic review of the literature on A&F interventions for improving test or transfusion ordering in the critical care setting.
Methods
Five databases, two registries, and the bibliographies of relevant articles were searched. We included critical care studies that assessed the use of A&F targeting healthcare provider behaviors, alone or in combination with other interventions to improve test and transfusion ordering, as compared to historical practice, no intervention, or another healthcare behaviour change intervention. Studies were included only if they reported laboratory test or transfusion orders, or the appropriateness of orders, as outcomes. There were no restrictions based on study design, date of publication, or follow-up time. Intervention characteristics and absolute differences in outcomes were summarized. The quality of individual studies was assessed using a modified version of the Effective Practice and Organisation of Care Cochrane Review Group’s criteria.
Results
We identified 16 studies, including 13 uncontrolled before-after studies, one randomized controlled trial, one controlled before-after study, and one controlled clinical trial (quasi-experimental). These studies described 17 interventions, mostly (88%) multifaceted interventions with an A&F component. Feedback was most often provided in a written format only (41%), more than once (53%), and most often only provided data aggregated to the group-level (41%). Most studies saw a change in the hypothesized direction, but not all studies provided statistical analyses to formally test improvement. Overall study quality was low, with studies often lacking a concurrent control group.
Conclusions
Our review summarizes characteristics of A&F interventions implemented in the critical care context, points to some mechanisms by which A&F might be made more effective in this setting, and provides an overview of how the appropriateness of orders was reported. Our findings suggest that A&F can be effective in the context of critical care; however, further research is required to characterize approaches that optimize the effectiveness in this setting alongside more rigorous evaluation methods.
Trial registration
PROSPERO CRD42016051941.
Funder
Queen Elizabeth II Scholarship
University of Ottawa Graduate Studies Scholarship
Ottawa Hospital Research Institute Graduate Studentship
Publisher
Springer Science and Business Media LLC
Subject
Public Health, Environmental and Occupational Health,Health Informatics,Health Policy,General Medicine
Reference85 articles.
1. Zhi M, Ding EL, Theisen-Toupal J, Whelan J, Arnaout R. The landscape of inappropriate laboratory testing: a 15-year meta-analysis. PLoS One. 2013;8(11):1–8.
2. Australian Association of Pathology Practices Inc. An analysis of pathology test use in australia. Family Medicine Research Centre, University of Sydney; 2011.
3. Cadogan SL, Browne JP, Bradley CP, Cahill MR. The effectiveness of interventions to improve laboratory requesting patterns among primary care physicians: a systematic review. Implement Sci. 2015;10:167.
4. Lewandrowski K, Baron J, Dighe A. Utilization management in the clinical laboratory: an introduction and overview. In: Lewandrowski K, Sluss P, editors. Utilization Management in the Clinical Laboratory and Other Ancillary Services. Springer, Cham; 2017.
5. Ezzie ME, Aberegg SK, O’Brien JM. Laboratory Testing in the intensive care unit. Crit Care Clin. 2007;23(3):435–65.