Automated meniscus segmentation and tear detection of knee MRI with a 3D mask-RCNN

Author:

Li Yuan-Zhe,Wang Yi,Fang Kai-Bin,Zheng Hui-Zhong,Lai Qing-Quan,Xia Yong-Fa,Chen Jia-Yang,Dai Zhang-sheng

Abstract

Abstract Background The diagnostic results of magnetic resonance imaging (MRI) are essential references for arthroscopy as an invasive procedure. A deviation between medical imaging diagnosis and arthroscopy results may cause irreversible damage to patients and lead to excessive medical treatment. To improve the accurate diagnosis of meniscus injury, it is urgent to develop auxiliary diagnosis algorithms to improve the accuracy of radiological diagnosis. Purpose This study aims to present a fully automatic 3D deep convolutional neural network (DCNN) for meniscus segmentation and detects arthroscopically proven meniscus tears. Materials and methods Our institution retrospectively included 533 patients with 546 knees who underwent knee magnetic resonance imaging (MRI) and knee arthroscopy. Sagittal proton density-weighted (PDW) images in MRI of 382 knees were regarded as a training set to train our 3D-Mask RCNN. The remaining data from 164 knees were used to validate the trained network as a test set. The masks were hand-drawn by an experienced radiologist, and the reference standard is arthroscopic surgical reports. The performance statistics included Dice accuracy, sensitivity, specificity, FROC, receiver operating characteristic (ROC) curve analysis, and bootstrap test statistics. The segmentation performance was compared with a 3D-Unet, and the detection performance was compared with radiological evaluation by two experienced musculoskeletal radiologists without knowledge of the arthroscopic surgical diagnosis. Results Our model produced strong Dice coefficients for sagittal PDW of 0.924, 0.95 sensitivity with 0.823 FPs/knee. 3D-Unet produced a Dice coefficient for sagittal PDW of 0.891, 0.95 sensitivity with 1.355 FPs/knee. The difference in the areas under 3D-Mask-RCNN FROC and 3D-Unet FROC was statistically significant (p = 0.0011) by bootstrap test. Our model detection performance achieved an area under the curve (AUC) value, accuracy, and sensitivity of 0.907, 0.924, 0.941, and 0.785, respectively. Based on the radiological evaluations, the AUC value, accuracy, sensitivity, and specificity were 0.834, 0.835, 0.889, and 0.754, respectively. The difference in the areas between 3D-Mask-RCNN ROC and radiological evaluation ROC was statistically significant (p = 0.0009) by bootstrap test. 3D Mask RCNN significantly outperformed the 3D-Unet and radiological evaluation demonstrated by these results. Conclusions 3D-Mask RCNN has demonstrated efficacy and precision for meniscus segmentation and tear detection in knee MRI, which can assist radiologists in improving the accuracy and efficiency of diagnosis. It can also provide effective diagnostic indicators for orthopedic surgeons before arthroscopic surgery and further promote precise treatment.

Funder

Fujian provincial health technology project

Publisher

Springer Science and Business Media LLC

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A Comprehensive Review on MRI-based Knee Joint Segmentation and Analysis Techniques;Current Medical Imaging Formerly Current Medical Imaging Reviews;2023-07-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3