Evaluation of the safety and efficacy of extracorporeal carbon dioxide removal in the critically ill using the PrismaLung+ device

Author:

Tiruvoipati RavindranathORCID,Ludski Jarryd,Gupta Sachin,Subramaniam AshwinORCID,Ponnapa Reddy MallikarjunaORCID,Paul Eldho,Haji Kavi

Abstract

Abstract Background Several extracorporeal carbon dioxide removal (ECCO2R) devices are currently in use with variable efficacy and safety profiles. PrismaLung+ is an ECCO2R device that was recently introduced into clinical practice. It is a minimally invasive, low flow device that provides partial respiratory support with or without renal replacement therapy. Our aim was to describe the clinical characteristics, efficacy, and safety of PrismaLung+ in patients with acute hypercapnic respiratory failure. Methods All adult patients who required ECCO2R with PrismaLung+ for hypercapnic respiratory failure in our intensive care unit (ICU) during a 6-month period between March and September 2022 were included. Results Ten patients were included. The median age was 55.5 (IQR 41–68) years, with 8 (80%) male patients. Six patients had acute respiratory distress syndrome (ARDS), and two patients each had exacerbations of asthma and chronic obstructive pulmonary disease (COPD). All patients were receiving invasive mechanical ventilation at the time of initiation of ECCO2R. The median duration of ECCO2R was 71 h (IQR 57–219). A significant improvement in pH and PaCO2 was noted within 30 min of initiation of ECCO2R. Nine patients (90%) survived to weaning of ECCO2R, eight (80%) survived to ICU discharge and seven (70%) survived to hospital discharge. The median duration of ICU and hospital stays were 14.5 (IQR 8–30) and 17 (IQR 11–38) days, respectively. There were no patient-related complications with the use of ECCO2R. A total of 18 circuits were used in ten patients (median 2 per patient; IQR 1–2). Circuit thrombosis was noted in five circuits (28%) prior to reaching the expected circuit life with no adverse clinical consequences. Conclusion(s) PrismaLung+ rapidly improved PaCO2 and pH with a good clinical safety profile. Circuit thrombosis was the only complication. This data provides insight into the safety and efficacy of PrismaLung+ that could be useful for centres aspiring to introduce ECCO2R into their clinical practice.

Publisher

Springer Science and Business Media LLC

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3