Author:
Zhao Hui-Ying,Zhang Jing-Shang,Li Meng,Chen Dong-Jun,Wan Xiu-Hua
Abstract
Abstract
Purpose
The aim of the study is to evaluate the effect of capsular tension ring (CTR) implantation following cataract surgery on the refractive outcomes of patients with extreme high axial myopia.
Methods
Sixty eyes (with an axial length of ≥26 mm) were retrospectively reviewed and classified into two groups: CTR group (n = 30), which underwent CTR implantation following phacoemulsification, and control group (n = 30), which did not undergo CTR implantation. Intraocular lens (IOL) calculation was performed using Barrett Universal II (UII), Haigis, and SRK/T formulas. The refractive prediction error (PE) was calculated by subtracting the postoperative refraction from predicted refraction. The mean PE (MPE), mean absolute error (MAE), and percentages of eyes that had a PE of ±0.25, ±0.50, ±1.00, or ±2.00 diopters (D) were calculated and compared.
Results
No significant differences were observed in PE between the two groups. The Barrett UII formula revealed a lower AE in the CTR group than in the control group (p = 0.015) and a lower AE than the other two formulas (p = 0.0000) in both groups. The Barrett UII formula achieved the highest percentage of eyes with a PE of ±0.25 D (66.67%).
Conclusions
The refractive outcomes were more accurate in eyes with CTR implantation than in those with routine phacoemulsification based on the Barrett UII formula. The Barrett UII formula was recommended as the appropriate formula when planning CTR implantation in high myopia.
Funder
the Beijing Hospitals Authority Clinical Medicine Development of special funding support