Abstract
AbstractRecently, renewable resources such as wind, hydro, and tidal have experienced a rapid development. Electricity production, based on wind, has been concentrated on a large scale. Additionally, a doubly fed induction generator has been used in wind farms on a large scale. This machine is influenced by the multiple transient states that are happening in the grid. Many researchers studied the effect of voltage-dip on DFIG performance; none of them studied the effect of voltage-dip sharing with wind-speed changing for both sub- and hyper-synchronous modes. In this paper, DFIG behavior is investigated under a transient state which is represented by 3-phase voltage-dip, in both operation modes (sub-synchronous & hyper-synchronous) with various values of the wind speed. Based on MATLAB Simulink, the various DFIG parameters are extracted to determine the relation between voltage-dip, variable wind speed, and DFIG performance. Results show that the parameters that are affected were rotor-current, rotor-voltage, and DC-Link voltage, while stator-current and stator-flux are not affected. It is also shown that DC-Link voltage values are smaller in the hyper-synchronous mode compared with sub-synchronous one.
Publisher
Springer Science and Business Media LLC
Reference35 articles.
1. Aljafari B, Pamela SJ, Vairavasundaram I, Singh RR (2022) Steady state modeling and performance analysis of a wind turbine-based doubly fed induction generator system with rotor control. Energies 15(9):3327. https://doi.org/10.3390/en15093327
2. Chhipą AA, Chakrabarti P, Bolshev V, Chakrabarti T, Samarin G, Vasilyev AN, Kudryavtsev A (2022) Modeling and control strategy of wind energy conversion system with grid-connected doubly-fed induction generator. Energies 15(18):6694. https://doi.org/10.3390/en15186694
3. Dannier A, Fedele E, Spina I, Brando G (2022) Doubly-fed induction generator (DFIG) in connected or weak grids for turbine-based wind energy conversion system. Energies 15(17):6402. https://doi.org/10.3390/en15176402
4. Singh R (2017) Contrast the performance of doubly fed induction generator during symmetrical and non-symmetrical fault condition by varying wind speed, Master Thesis, School of Electronics and Electrical Engineering, Phagwara, Punjab
5. Alshibani A, Hasanah, R, Suyono H (2018) Grid voltage dip impacts on the DFIG wind turbine and its main AC contactor performances. Jurnal EECCIS; p. 54–60. doi: https://doi.org/10.21776/jeeccis.v12i2.523
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献